HANNA HI93703


Darmatek Alat Ukur dan Instrument

Description :

HANNA HI 93703 Portable Logging Turbidity Meter
ISO Compliant
  • GLP Features
  • 3 point calibration
  • Logging for up to 199 measurements (HI 93703-11)
  • PC Connectivity (HI 93703-11)
HI 93703 series are microprocessor based turbidity meters that provide laboratory accuracy for field turbidity measurements.

The HI 93703 is easy to calibrate (with 3 point calibration) using AMCO-EPA standards and is ISO 7027 compliant.

HANNA instruments has chosen 10 FTU* as the calibration point because it is the value that best fits the water turbidity measurements in different applications, from drinking water to wastewater treatment. HANNA instruments uses the primary standard AMCO-AEPA-1 to avoid all formazine-related problems. Formazine is a very toxic, unstable substance which requires particular care: its standards have to be prepared only a few minutes before performing the calibration, and cannot be reused because of their short life. HANNA AMCO-AEPA-1 standards are extremely stable, can be reused, and last up to six months if free from contamination. HI 93703 can be used with both standards.

The HI 93703-11 enhanced version features a real-time clock, logging for up to 199 measurements and PC compatibility via the RS232 interface and Windows® compatible HI 92000 software.
Both versions meet the requirements of GLP (Good Laboratory Practice) protocols for last calibration data storage.

Order Information:
HI 93703 is supplied complete with glass cuvette, batteries and instructions.

Specification

Range

0.00 to 50.00 FTU;
50 to 1000 FTU

Resolution

0.01 FTU (0.00 to 50.00 FTU);
1 FTU (50 to 1000 FTU)

Accuracy

±0.5 FTU or ±5% of reading (whichever is greater)
Calibration

3 points (0 FTU, 10 FTU and 500 FTU)
Light Source

infrared LED
Light Detection

Silicon Photocell
Battery Type / Life

1.5V AA (4) /approximately 60 hours of continuous use or 900 measurements; auto-off after 5 minutes of non-use
Environment

0 to 50°C (32 to 122°F); RH max 95% non-condensing
Dimensions

220 x 82 x 66 mm (8.7 x 3.2 x 2.6")
Weight

510 g (1.1 lb.)

HANNA HI 93102


Darmatek Alat Ukur dan Instrument

Description :

HANNA HI 93102 Complete Tool for Water Analysis
Turbidity, Cl2, pH, Br, Fe, I and CYS
  • USEPA Compliance. In the turbidimetric mode, the HI 93102 uses the nephelometric principle according to USEPA’s 180.1 method and the Standard Method 2130B.
  • Custom Calibration Points. Advanced electronics allow operators to calibrate the meter at a selectable point in from 0.00 to 50.00 NTU.
  • Logging Capability. The HI 93102 makes it possible to log and retrieve up to 25 different samples.
The most important parameters needed for water analysis, especially in drinking water, can be measured with HANNA’s HI 93102 portable meter. This instrument not only measures turbidity, but also pH, total and free chlorine, bromine, iodine, iron, and cyanuric acid (CYS). Achieve laboratory results in the field quickly and easily.

Measurements are made quickly and repeatedly through a sophisticated, yet easy-to-use microprocessor. In colorimetric mode, users can select between factory preprogrammed calibration or calibrating the meter on their own, and measure either concentration or relative absorbance of the sample. Up to 25 measured samples can be stored in memory together with time and date. Miniaturization of the electronics has made it possible to offer unsurpassed accuracy and quality in a portable unit weighing just one pound!

Order Information:
HI 93102 is supplied with measurement cuvette cap, batteries and instruction manual.

Specifications

Range
Turbidity
0.00 to 9.99 NTU / 0.00 to 50.0 NTU
  Bromine
0.00 to 8.00 mg/L (ppm)
  Free Cl2
0.00 to 2.50 mg/L (ppm)
  Total Cl2
0.00 to 3.50 mg/L (ppm)
  CYS
0 to 80 mg/L (ppm)
  Iodine
0.0 to 12.5 mg/L (ppm)
  Iron LR
0.00 to 1.00 mg/L (ppm)
  pH
6.5 to 8.5 pH
Resolution
Turbidity
0.01 and 0.1 NTU
  Bromine
0.01 mg/L (ppm)
  Free and
Total Cl2

0.01 mg/L (ppm)
  CYS
1 mg/L (ppm)
  Iodine
0.1 mg/L (ppm)
  Iron LR
0.01 mg/L (ppm)
  pH
0.1 pH
Accuracy @25°C
Turbidity
±0.5 NTU or ±5% of reading (whichever is greater)
  Bromine
±0.08 mg/L (ppm) ±3% of reading
  Free and
Total Cl2

±0.03 mg/L (ppm) ±3% of reading
  CYS
±1 mg/L (ppm) ±15% of reading
  Iodine
±0.1 mg/L (ppm) ±5% of reading
  pH
±0.1 pH
Calibration

two points; selectable between 0.00 - 50.0 FTU (0.00 and 20.0 FTU recommended)
Light Source

pure green LED
Light Detector

silicon photocell
Battery Type / Life

1.5V AA (4) / approximately 60 hours of continuous use or 1000 measurements; automatic shut-off selectable after 10, 20, 30, 40, 50 or 60 minutes
Environment

0 to 50°C (32 to 122°F); RH max 95% (non condensing)
Dimensions / Weight

220 x 82 x 66 mm (8.7 x 3.2 x 2.6’’) / 510 g (1.1 lb.)

HANNA HI93414

Darmatek Alat Ukur dan Instrument

Description :

HANNA HI 93414 Turbidity and Free/Total Cl2 Portable Meter
with CAL CHECK™ and Fast Tracker™, EPA Compliant
  • High accuracy at low ranges   
  • Exclusive chlorine CAL CHECK™ calibration validation
  • Exclusive Fast Tracker™ system
  • User replaceable light source
  • Two, three or four point turbidity calibration
  • USB and RS232 PC connectivity
  • GLP features
  • Logging for up to 200 readings
  • User friendly, backlit  display with guidance codes
  • Auto-off
  • Battery % on startup
  • Continuous current time on display
The HI 93414 measures the most important parameters of drinking water: turbidity and free/total chlorine. Designed for water quality measurements, HI 93414 provides reliable and accurate readings on low turbidity and chlorine values. The HI 93414 meets and exceeds the requirements of USEPA and Standard Methods both for turbidity and colorimetric measurements.

This instrument incorporates an optical system which guarantees accurate results. The optical system, consisting of a tungsten filament lamp, three detectors (scattered, transmitted for turbidimeter range and one for colorimeter range), and a narrow band interference filter @ 525 nm assures long term stability and minimizes stray light and color interferences. It also compensates for variations in intensity of the lamp, making no need for frequent calibration. The 25 mm round cuvettes made from special optical glass guarantee repeatability and consistency of measurements.

Turbidity measurements can be made in the 0.00 to 1000 NTU (Nephelometric Turbidity Units) range. The instrument has an EPA compliance reading mode which rounds readings to meet EPA reporting requirements. Depending on the measured sample and needed accuracy, normal measurement, continuous measurement or signal averaging measurement can be selected. Free or total chlorine measurements can be made in the 0.00 to 5.00 mg/L (ppm) range.
At startup, the meter displays the percentage of remaining battery life and, if too low, a 'low battery' warning message is displayed.

With the powerful CAL CHECK™ function, performance of the instrument can be validated at any time by using the exclusive HANNA ready-made NIST traceable standards. Calibration can be performed at any time for turbidity and colorimetric range. For turbidity, a two, three or four-point calibration is available using supplied (<0.1, 15, 100 and 750 NTU adjustable calibration points) or user prepared standards. For colorimeter measurements, a one-point calibration can be performed.

HI 93414 has complete GLP (Good Laboratory Practice) functions that allow traceability of the calibration conditions. The last calibration points, time and date can be checked at the touch of a button. HI 93414 has a user-friendly interface with an easy to read, large (LCD). Displayed codes guide the user step by step with routine operation and through calibration. Confirmation and error acoustic signals aid the user during instrument operation.

For advanced field applications, the HI 93414 is equipped with Fast Tracker™—Tag Identification System (T.I.S.) that makes data collecting and management simpler than ever. Fast Tracker™ allows users to record the time and location of a specific measurement or series of measurements.
With it’s logging function, up to 200 measurements along with it’s tagged locations can be stored in internal memory and consulted at any time. Data can be later transferred to a PC via RS232 or USB interface and HANNA HI 92000 software (optional).

Order Information:

HI 93414-01 (115V) and HI 93414-02 (230V) is supplied with sample cuvettes and caps (5), calibration cuvettes for turbidimeter, calibration cuvettes for colorimeter, silicone oil, cuvette wiping tissue, scissors, batteries, AC adapter, instructions and rugged carrying case.

Specification

Range
Turbidity
0.00 to 9.99; 10.0 to 99.9 and 100 to 1000 NTU
  Free and
Total Cl2

0.00 to 5.00 mg/L
Resolution
Turbidity
0.01 NTU from 0.00 to 9.99 NTU; 0.1 NTU from 10.0 to 99.9 NTU; 1 NTU from 100 to 1000 NTU
  Free and
Total Cl2

0.01 mg/L from 0.00 to 3.50 mg/L; 0.10 above 3.50 mg/L
Accuracy @25°C
Turbidity
±2% of reading plus 0.02 NTU
  Free and
Total Cl2

±0.03 mg/L ±3%  of reading (whichever is greater)
Method
Turbidity
Ratio Nephelometric Method (90°), ratio of scattered and transmitted light; adaptation of the USEPA Method 180.1 and Standard Method 2130 B
  Free and Total Cl2
adaptation of the USEPA Method 330.5 and Standard Method 4500-Cl G. The reaction between chlorine and DPD reagent causes a pink tint in the sample.
Standards
Turbidity
<0.1, 15, 100 and 750 NTU
  Free and Total Cl2
1 mg/L free chlorine, 1 mg/L total chlorine
Calibration
Turbidity
two, three or four-point calibration
  Free and Total Cl2
one-point calibration
Light Detector
Turbidity
silicon photocell
  Free and
Total Cl2

silicon photocell with 525 nm narrow band interference filter
Turbidity Range
Selection


automatic
Stray Light

< 0.02 NTU
Measuring Mode

normal, average, continuous
Light Source

tungsten filament lamp
Lamp Life

greater than 100,000 readings
Log Memory

200 records
Serial Interface

USB or RS 232
Environment

0°C (32°F) to 50°C (122°F); max 95% RH non-condensing
Power Supply

1.5V AA alkaline batteries (4) or AC adapter; auto-off after 15 minutes of non-use
Dimensions / Weight

224 x 87 x 77 mm (8.8 x 3.4 x 3.0”) / 512 g (18 oz.)

HANNA HI98703

Darmatek Alat Ukur dan Instrument

Description :

HANNA HI 98703 Turbidity Meter
with Fast Tracker™ Technology, EPA Compliant
  • High accuracy at low ranges (below 0.05 NTU)
  • Two, three or four point calibration
  • USB and RS232 PC connectivity
  • Log up to 200 records
  • GLP Features
  • User friendly, backlit  display with guidance codes
  • Battery % on startup
  • Continuous current time on display
The HI 98703 meets and exceeds the requirements of the USEPA Method 180.1 for wastewater and Standard Method 2130 B for drinking water. The instrument has an EPA compliance reading mode which rounds readings to meet EPA reporting requirements. Users will appreciate the accuracy and sensitivity of this instrument, particularly at very low turbidity levels.

This instrument incorporates complete GLP (Good Laboratory Practice) functions that allow traceability of the calibration conditions. The last calibration points,  time and date can be checked at the touch of a button.

With it’s logging function, up to 200 measurements along with it’s tagged locations can be stored in internal memory and consulted at any time. Data can be later transferred to a PC via RS232 or USB interface and HANNA HI 92000 software (optional).

Exclusive Fast Tracker™
For advanced field applications, the HI 98703 is equipped with Fast Tracker™—Tag Identification System (T.I.S.) that makes data collecting and management simpler than ever. Fast Tracker™ allows users to record the time and location of a specific measurement or series of measurements.

Order Information:
HI 98703-01 (115V), HI 98703-02 (230V) and HI 98703-03 (AUS plug) are supplied with sample cuvettes and caps (5), HI 98703-11 calibration cuvettes, HI 93703-58 silicone oil, cuvette cleaning cloth, batteries, AC adapter, instruction manual and rugged carrying case.

Specifications

Range

0.00 to 9.99; 10.0 to 99.9 and 100 to 1000 NTU
Range Selection

automatic
Resolution

0.01 NTU from 0.00 to 9.99 NTU; 0.1 NTU from 10.0 to 99.9 NTU; 1 NTU from 100 to 1000 NTU
Accuracy @25°C

±2% of reading plus 0.02 NTU
Repeatability

±1% of reading or 0.02 NTU, whichever is greater
Stray Light

< 0.02 NTU
Light Detector

silicon photocell
Light Source

tungsten filament lamp
Lamp Life

greater than 100,000 readings
Method

Ratio Nephelometric Method (90°), ratio of scattered and transmitted light; Adaptation of the USEPA Method 180.1 and Standard Method 2130 B
Measuring Mode

normal, average, continuous
Turbidity Standards

<0.1, 15, 100 and 750 NTU
Calibration

two, three or four-point calibration
Log Memory

200 records
PC Connectivity

USB or RS232
Environment

up to 50°C (122°F); RH max 95% non-condensing
Power Supply

1.5V AA alkaline batteries (4) or AC adapter; auto-off after 15 minutes of non-use
Dimensions / Weight

224 x 87 x 77 mm (8.8 x 3.4 x 3.0”) / 512 g (18 oz.)

HANNA HI 88713

Darmatek Alat Ukur dan Instrument

Description :

HANNA HI 88713 Turbidity Benchtop Meter, ISO

  • Graphic display, backlit LCD
  • Two, three, four or five point calibration
  • GLP features
  • Log up to 200 records
  • Contextual help and tutorial mode
  • USB PC connectivity
The HI 88713 turbidity bench meter meets and exceeds the requirements of the
ISO 7027 standard.

HI 88713 is based on an optical system which guarantees accurate results, long term stability and minimizes stray light and color interferences. It also compensates for variations in intensity of the LED, limiting the need for frequent calibration.
Depending on the measured sample and needed accuracy, normal, continuous or signal averaging measurement can be selected.

A two, three, four or five-point calibration can be performed using the supplied standards. Calibration points can be modified when user prepared standards are used.
The HI 88713 turbidity bench meter has complete GLP (Good Laboratory Practice) functions that allow traceability of the calibration conditions.

The HI 88713 turbidity bench meter has a user-friendly interface with an easy to understand, graphic LCD. Comprehensive contextual help is available at a simple key press. Furthermore, a tutorial mode of operation guides the user step by step through the analysis process.
Up to 200 measurements can be stored in internal memory. Data can be transferred to a PC via optional HI 920013 USB cable and HI 92000 Windows® compatible software.

Order Information:
HI 88713-01 (115V) and HI 88713-02 (230V) are supplied with sample cuvettes and caps (6), calibration cuvettes, silicone oil, tissue for wiping cuvettes, power adapter and instruction manual.
 
Specifications


Range FNU Mode 0.00 to 9.99; 10.0 to 99.9; 100 to 1000 FNU
FAU Mode 10.0 to 99.9; 100 to 4000 FAU
NTU Ratio Mode 0.00 to 9.99; 10.0 to 99.9; 100 to 4000 NTU 0.00 to 9.99; 10.0 to 99.9; 100 to 980 EBC
NTU Non-Ratio Mode 0.00 to 9.99; 10.0 to 99.9; 100 to 1000 NTU 0.00 to 9.99; 10.0 to 99.9; 100 to 245 EBC
Resolution FNU Mode 0.01; 0.1; 1 FNU
FAU Mode 0.1; 1 FAU
NTU Ratio Mode 0.01; 0.1; 1 NTU / 0.01; 0.1; 1 EBC
NTU Non-Ratio Mode 0.01; 0.1; 1 NTU / 0.01; 0.1; 1 EBC
Accuracy @25°C FNU Mode ±2% of reading plus stray light
FAU Mode ±10% of reading
NTU Ratio Mode ±2% of reading plus stray light / ±5% of reading above 1000 NTU
NTU Non-Ratio Mode ±2% of reading plus stray light
Range Selection
automatic
Repeatability
±1% of reading or stray light, whichever is greater
Stray Light
< 0.1 NTU (0.05 EBC)
Light Detector
silicon photocell
Light Source
IR LED
Method
ISO 7027 Method
Measuring Mode
normal, average, continuous.
Turbidity Standards
<0.1, 15, 100, 750 FNU and 2000 NTU
Calibration
two, three, four or five-point calibration
Log Memory
200 records
PC Connectivity
USB
Environment
0°C (32°F) to 50°C (122°F); max 95% RH non-condensing
Power Supply
12 Vdc power input
Dimensions / Weight
230 x 200 x 145 mm (9 x 7.9 x 5.7”) / 2.5 Kg (88 oz.)

HANNA HI 88703

Darmatek Alat Ukur dan Instrument

Descritpion :

HANNA HI 88703 Precision Turbidity Benchtop Meter, EPA Compliant
  • Two measuring ranges: Ratio turbidity, non-ratio turbidity
  • Meets USEPA requirements
  • GLP features       
  • Two, three, four or five point turbidity calibration
  • USB PC connectivity
  • Log up to 200 measurements
  • Contextual help and tutorial mode
The HI 88703 turbidity benchtop meter is specially designed for water quality measurements, providing reliable and accurate readings on low turbidity ranges.
This instrument has an EPA compliance reading mode which rounds the reading
to meet EPA reporting requirements. Alternative EBC and Nephelos measuring units are available. Depending on the measured sample and needed accuracy, normal, continuous or signal averaging measurement can be selected.

A two, three, four or five-point calibration could be performed by using the supplied standards. When user prepared standards are used, calibration points can be modified.
H 88703 features complete GLP (Good Laboratory Practice) functions that allows traceability of the calibration conditions. The last calibration points, time and date can be checked.
Up to 200 measurements can be stored in internal memory. Data can be transferred to a PC via optional HI 920013 USB cable and HI 92000 Windows® compatible software.

Order Information:
HI 88703-01 (115V) and HI 88703-02 (230V) is supplied with sample cuvettes and caps (5), calibration cuvettes, silicone oil (HI 93703-58), tissue for wiping cuvettes, power cord and instruction manual.

Specifications

Range
Non Ratio Mode
0.00 to 9.99; 10.0 to 40.0 NTU;
0.0 to 99.9; 100 to 268 Nephelos
0.00 to 9.80 EBC

  Ratio Mode
0.00 to 9.99; 10.0 to 99.9; 100 to 4000 NTU
0.0 to 99.9; 100 to 26800 Nephelos
0.00 to 9.99; 10.0 to 99.9; 100 to 980 EBC

Resolution
Non Ratio Mode
0.01; 0.1 NTU 0.1; 1 Nephelos; 0.01 EBC
  Ratio Mode
0.01; 0.1; 1 NTU 0.1; 1 Nephelos 0.01; 0.1, 1 EBC
Range Selection

automatic
Accuracy @25°C

±2% of reading plus 0.02 NTU (0.15 Nephelos; 0.01 EBC)
±5% of reading above 1000 NTU (6700 Nephelos; 245 EBC)

Repeatability

±1% of reading or 0.02 NTU (0.15 Nephelos; 0.01 EBC)whichever is greater
Stray Light

< 0.02 NTU (0.15 Nephelos; 0.01 EBC)
Light Detector

silicon photocell
Method

Nephelometric method (90°) or Ratio Nephelometric Method(90° & 180°), Adaptation of the USEPA Method 108.1 and Standard Method 2130 B.
Measuring Mode

normal, average, continuous
Turbidity Standards

<0.1, 15, 100, 750 and 2000 NTU
Calibration

two, three, four or five-point calibration
Light Source/Life

tungsten filament lamp / greater than 100,000 readings
Display

40 x 70 mm graphic LCD (64 x 128 pixels) with backlight
Log Memory

200 records
PC Interface

USB
Environment

0°C (32°F) to 50°C (122°F); max 95% RH non-condensing
Power Supply

230 V/50 Hz or 115 V/60 Hz 20 W; auto-off after 15 minutes of non-use
Dimensions

230 x 200 x 145 mm (9 x 7.9 x 5.7”)
Weight

2.5 Kg (88 oz.)

Lutron TU2016

Darmatek Alat Ukur dan Instrument

Lutron Turbidity Meter

Model : TU-2016
* Range : Auto range, two ranges, 0.00 to 50.00 NTU, 50 to 1,000 NTU.
* Resolution : 0.01 NTU/1 NTU.
* Accuracy : 5 % F.S. or 0.5 NTU, which ever is greater.
* Light source : LED, 850 nm.
* Record Max, Min value.
* Power : 1.5 V battery (UM-4/AAA) x 6 PCs.
* 0 NTU and 100 NTU Calibration solution are included.
* Designed to meet ISO 7027.

Orbeco TB200

Darmatek Alat Ukur dan Instrument

Description :
 
The TB200TM Portable Turbidimeter from Orbeco-Hellige allows fast and easy turbidity measurement in both the field and in the laboratory.

Using a “white light” source and 90° detection, the TB200 meets the USEPA specifications for turbidity measurement (EPA Standard 180.1). Also available in an Infrared version, the TB200-IR is ISO 7027 compliant.

The instrument features an auto-ranging function that automatically selects the correct turbidity range for your sample. Calibration is simple with the included calibration standards.
A power efficient microcircuit design allows the instrument to yield 5,000 tests on 4-AA alkaline batteries with an estimated 7 to 10 year bulb life. Integrated diagnostics confirm proper operation and accuracy.

Spesifications:

Range: 0 – 1100 NTU (auto-ranging)
   
Resolution: < 100 NTU:            0.01 NTU
100 – 999 NTU:       0.1 NTU
1000 – 1100 NTU:    1 NTU
   
Accuracy: ± 2%:  0 – 500 NTU
± 3%:  500 – 1000 NTU
   
Response Time: 14 Seconds
   
Power Supply: 4 x AA Batteries
   
Dimensions: 8.25 x 3.75 x 7.75 inches
   
Insulation Rating: Pollution Degree 2
   
Operating Temperature Range: 0 – 50°C
   
Sample Temperature Range: 0 – 50°C
   
Principle of Operation: Nephelometric
   
Light Source: TB200:  Tungsten Lamp TB200-IR:  860 nm LED
   
Sample Cell Volume: 10 ml
   
Battery Life: ~5,000 tests
   
Bulb Life: 7 – 10 years
   
Conformance: TB200:  US EPA Method 180.1 TB200-IR:  ISO 7027
   
Certification: CE