Fluke 123 Industrial Scopemeter

Darmatek Alat Ukur dan Instrument

Fluke 123 Industrial Scopemeter
FIND FAST ANSWERS TO PROBLEMS IN MACHINERY, INSTRUMENTATION, CONTROL AND POWER SYSTEMS

INSTRUMENT FEATURES
The rugged and compact Fluke 123 ScopeMeter is the ideal solution for industrial troubleshooting and installation applications.
In today’s complex systems, a meter measurement just doesn’t give enough detail to determine the cause of a fault. Signal anomalies, drop-outs and glitches that might cause a machine to go down, are best displayed with an oscilloscope. The ScopeMeter 120 Series meet today’s need of simultaneously measuring and checking waveforms.
The Fluke 123 is a truly integrated test tool, with oscilloscope, multimeter & paperless recorder in one affordable, easy to use instrument.

Fluke 123 Industrial Scopemeter Features
Dual-input 20 MHz digital oscilloscope.
Two 5,000 counts true-RMS digital multimeters.
A dual-input TrendPlot recorder.
Connect-and-View trigger simplicity for .hands-off operation.
Shielded test leads for oscilloscope, resistance and continuity.
600 V CAT III safety certified.
Optically isolated RS-232 interface.
Rugged, compact case.
Memory: 10 screens and setups.
Dimensions: 232 x 115 x 50mm.
Weight: 1.2kg.

Included Accessories:
PM907 battery charger/line voltage adaptor, STL120 shielded test leads set, AC120 alligator clips, HC120 hook clips, BB120 shielded BNC adaptor, Fluke 123 user manual & BP120 rechargeable battery pack.

Fluke 125 Dual-input Industrial Scopemeter

Darmatek Alat Ukur dan Instrument

Fluke 125 Dual-input Industrial Scopemeter
THE FLUKE 125 VALIDATES THE QUALITY OF THE ELECTRICAL SIGNALS AS SOON AS ANY ELECTRICAL SIGNALS ARE PASSED ALONG THE NETWORK

INSTRUMENT FEATURES
The Fluke 125 is the ScopeMeter of choice for the maintenance engineer who deals with industrial machinery and the industrial network connecting his machinery.
The Fluke 125 is based on the Fluke 124 and includes all the functions and capabilities of that instrument. On top, a Bus Health Test mode allows for an analysis of the signal quality on industrial buses and networks, comparing measured signals to the standards' signal requirements.

Fluke 125 Industrial Scopemeter Features
Dual-input 40 MHz digital oscilloscope.
Two 5,000 counts true-RMS digital multimeters.
A dual-input TrendPlot recorder.
Bus Health Test for industrial bus systems.
Automatic measurements.
Connect-and-View trigger simplicity.
Power Measurements for single and balanced 3-phase systems.
Harmonics mode.
RPM and Hz readings.
Vac pwm for use on motor drive outputs.
Up to 7 hours battery operation.
600V CAT III safety certified.
Optically-isolated interface for PC connection.
Dimensions: 232 x 115 x 50mm.
Weight: 1.2 kg.

Included Accessories:
PM 8907 line adapter/charger, STL120 shielded test leads set (1 red, 1 grey), AC120 Alligator Clips, HC120 Hook Clips, BB120 shielded BNC adapter, BP120MH NiMH battery pack, VPS40 wide bandwidth Voltage Probe, TL75 hard point test lead, i400s current clamp, Getting Started booklet, Fluke 125 user's manual (cd-rom).

Fluke 190-104 4-Channel Industrial Scopemeter (100MHz)


 Darmatek Alat Ukur dan Instrument

Fluke 190-104 4-Channel Industrial Scopemeter (100MHz)

THE FIRST HIGH-PERFORMANCE FOUR-CHANNEL SCOPES BUILT FOR HARSH INDUSTRIAL ENVIRONMENTS

INSTRUMENT FEATURES

This is the base model that only includes the scopemeter.
As the first four-channel portable scopes safety rated CAT III 1000V / CAT IV 600V, the Fluke ScopeMeter 190 Series II combines an unprecedented level of performance, ruggedness, and portability.
The Fluke ScopeMeter 190-104 (100MHz) and 190-204 (200MHz) combine the highest safety ratings and rugged portability with the high performance of a bench oscilloscope. Designed for plant maintenance engineers and technicians, these tough ScopeMeters go into harsh, dirty, and hazardous industrial conditions to test everything from microelectronics to power electronics applications.

Fluke 190-104 100MHz ScopeMeter Features

Bandwidth: Fluke 190-104: 100 MHz.
Real-time sample rate: Fluke 190-104: 1.25 GS/s.
Four electrically isolated inputs.
CAT III 1000V / CAT IV 600V safety rated.
Single shot, pulse width, and video triggering.
Deep memory: 10,000 samples per channel waveform capture so you can zoom in on the details.
Isolated USB ports for memory devices and PC connectivity.
8-hour battery life, standard with new Li-ion technology.
Easy-access battery door to make it easy to swap batteries.
A handy slot to tether and lock down the oscilloscope while unattended.
Display: 153 mm full color LCD with fast update rate.
Waveform Compare: Waveform reference with automatic Pass/Fail testing.
Dimensions: 270 x 190 x 70 mm.
Weight: 2.2kg (4.8lb).

Included Accessories:

Set of four probes, Hanging strap, USB cable, Li-ion battery BP291, a FlukeView demo package and Fluke 190-104 users manuals on CD-ROM

VOM VOS-6100 CRT Readout Analog Oscilloscope

Darmatek Alat Ukur dan Instrument

VOM VOS-6100 CRT Readout Analog Oscilloscope

Features
  1. 100MHz Bandwidth, Dual Channel, Delayed Sweep
  2. Built-In 6 Digit Universal Counter
  3. 10 Sets Memory for Front Panel Setting Save Recall
  4. Time Base Auto-Range
  5. Cursor Readout with 7 Measurement
  6. Panel Setup Lock of Digital-Control Functions
  7. Buzzer Alarm
  8. LED Indicator
  9. TV Synchonization
  10. Trigger Signal Output
  11. Z-Axis Modulation Input
  12. SMD Technology, High Stability and Reliability

Specification
Cursor Measurement
  • Cursor Measurement Function : T, 1/ T, V; P ( t, v)
  • Cursor Readout Function
  • Cursor Resolution : 1 / 25 DIV
  • Effective Cursor Range Vertical : V/ DIV, AC/ DC/ GND, CH1, CH2, INV, ALT, CHOP, ADD; Horizontal : TIME? DIV, x1/ x10) , X-Y
Horizontal System
  • Horizontal Modes : MAN ( A) , ALT, DELAY ( B)
  • A ( main) Sweep Time : 50nS ~ 0.5S/ DIV, continuously variable ( UNCAL)
  • B ( delay) Sweep Time : 50nS ~ 50mS/ DIV
  • Accuracy : ± 3 % ( ± 5 % at x 10MAG)
  • Sweep Magnification : x10 ( maximum sweep time 5nS/ DIV)
  • Hold OFF Time : Variable
  • Delay Time : 1µ S ~ 5S
  • Delay Jitter : 1/ 20000 or less
  • Alternate Separation : Variable
X-Y Mode
  • Sensitivity : X-axis, Y-axis selectable
  • X-Axis : CH1, CH2 ’ 2mV ~ 5V/ DIV ± 3%
  • Y-Axis : CH1, CH2 ’ 2mV ~ 5V/ DIV ± 3%
  • EXT ’ 0.1V/ DIV ± 5%
  • X-Axis Bandwidth : DC ~ 500KHz ( -3dB)
  • Phase Error : 3° or less at DC ~ 50KHz
Cursor Readout Function
  • Cursor Resolution : 1/ 100DIV
  • Effective Cursor Range : Vertical : ± 3DIV, Horizontal : ± 4DIV
  • Cursor Measurement Function : V, V% , VdB, T, 1 / T, T% ,
  • Panel Setting :
    • Vertical : V/ DIV ( CH1, CH2) , UNCAL, ADD, INV, P10, AC/ DC/ GND
    • Horizontal : S/ DIV ( MTB, DTB) , UNCALx 10, Delay time Hold-off
    • Trigger : Source, Coupling, Slope, Level, TV-H
    • Others : X-Y, LOCK, SAVE / RECALL, MEM 0-9
CRT
  • Type : 6-inch rectangular type with internal graticule 0% , 10% , 90% and 100% markers. 8x10DIV ( 1 DIV = 1 cm)
  • Phosphor : P31
  • Accelating Potensial : 16KV approx
  • Illumination : Continuous adjustable
Vertical Deflection System
  • Sensitivity : 2mV ~ 5V/ DIV, 11 step in 1-2-5 sequence
  • Sensitivity Accuracy : 3% ( 5DIV : at the center display)
  • Vernier Vertical Sensitivity : Continuosly variable to 1 / 2.5 or less than panel-indicated value
  • Frequency Bandwidth ( -3dB) : DC ~ 100MHz ( 2mV/ DIV : DC ~ 20MHz)
  • Rise Time : 3.5ns ( 2mV/ DIV : 17.5ns)
  • Signal Delay : Leading edge can be monitored
  • Maximum Input Voltage : 400V ( DC + AC) at 1KHz or less
  • Input Impedance : 1M& ± 2% / / 25pF approx
  • Vertical Modes : CH1, CH2, DUAL ( CHOP / ALT) , ADD ( DIFF mode can be established when the CH2 is in the INV mode)
  • CHOP Repetition Frequency : Approx. 250KHz
  • Polarity ( INV) : CH2 only
  • Bandwidth Limited : 20MHz
  • Common-mode Rejection Ration : 50: 1 or better at 50KHz
Trigger System
  • Trigger Modes : AUTO, NORM, TV
  • Trigger Source : CH1, CH2, LINE, EXT
  • Trigger Couplig : AC, DC, HFR, LFR
  • Trigger Slope : + / - polarity or TV sync polarity
  • Trigger Sensitivity :
    • AUTO : 10Hz ~ 20MHz, 0.35DIV, 50mVpp ( 20MHz ~ 100MHz) 1.5DIV, 150mVpp
    • NORM : DC ~ 20MHz, 0.35DIV, 50mVpp ( 20MHz ~ 100MHz) 1.5DIV, 150mVpp
    • TV : Sync signal, 1DIV, 200mVpp
    • Trigger Level Range :
      • INT : ± 4DIV or more
      • EXT : ± 0.4DIV or more
      • TV Sync : TV-V, TV-H
      • Max. External Inout Voltage : 400V ( DC + AC peak) at 1KHz
      • External Input Impedance : 1M& ± 5% // 25pF approx
Z-Axis Input
  • External intensity modulation
  • Coupling : DC
  • Voltage : 5V or more
  • Maximum Input Voltage : 30V ( DC + AC peak) at 1KHz or less
  • Bandwidth : DC ~ 5MHz
Trigger Signal Output
  • Voltage : 25mV/ DIV approx. in 50& termination
  • Frequency Response : DC ~ 10MHz
  • Output Impedance : 50& approx
Calibration Output
  • Waveform : 1KHz ± 5% , square wave
  • Voltage : 2Vpp ± 2%
  • Impedance : 2k& approx
Special Function
  • TIME / DIV Auto Range ( MOS-6103 / 6061 / 6060) : Provided
  • Panel Setting Save Recall ( MOS-6103 / 6061 / 6060) : 10 set
  • Panel Setups Lock : Provided

ATTEN ADS-1152CA Digital Oscilloscope


Darmatek Alat Ukur dan Instrument

ATTEN ADS-1152CA Digital Oscilloscope
  • The volume exquisite and it is convenient for carrying
  • Used Colored TFT LCD, the waveform display is clearer and stable
  • Dual channel-channel bandwidth 60MHZ-150MHZ
  • The real time sampling rate is 1GSa/s
  • Memory depth of ADS1000CA is 18Kpts
  • Trigger Models: Edge, Pulse, Video, Slope, Alternative and Delay trigger modes
  • Unique Digital Filter function and Waveform recorder function
  • Pass/Fail function
  • Thirty two parameters Auto measure function
  • Cursor measure covers Manual mode, Track mode and Auto mode
  • Channel waveform and its FFT waveform display on split screen
  • Pop-up Menu display pattern is more convenient for users using it
  • Multiple Language User Interface

Specification
MODEL INDEX ADS1152CA ADS1102CA ADS1062CA
Bandwidth 150MHz 100MHz 60MHz
Sampling Rate 1GSa/s
Equivalent Sampling Rate 50GSa/s

Memory Depth Single Channel: 2M; Double Channels: 1M/CH
Rise Time
Input Impedance 1MΩ||13pF
Sec/div Range 2.5ns/div-50s/div 5ns/div-50s/div
Roll:100ms-50s/div
Display Color TFT(320*234)5.7” LCD
The Common Specifications Of All ADS1000 Series Products
Display 12 divides full screen display
Channels 2
Vertical Sensitivity 2mv-5v/div(1-2-5 Sequence)
Vertical Resolution 8bit
Input coupling DC, AC, GND
Input Max voltage 400V(Vpp)
Trigger Types Edge, Pulse, Video, Slope, Alternative, Delay
Trigger Modes Auto, Normal, Single
Trigger Source CH1, CH2, Ext, Ext/5, AC Line
Save/Recall Provide two groups reference waveforms, twenty groups capture waveforms and twenty groups setups internal save/recall function and USB flash drive Save/Recall function
Auto Measure Types Vpp, Vmax, Vmin, Vamp, Vtop, Vbase, Vavg, Mean, Vrms, Crms, ROVShoot, FOVShoot, RPREShoot, FPREShoot, Freq, Period, Rise time, Fall Time, +Width, -Width, +Duty, - Duty, BWid, Phase, FRR, FRF, FFR, FFF, LRR, LRF, LFR, LFF
Cursor measure Manual, Track, Auto
Sample Types Real Time, Equivalent Time
Averages 4, 16, 32, 64, 128, 256
Math +, -, *, /, Invert
FFT Window: Hanning, Hamming, Blackman、Rectangular
Sampling Points: 1024 points
XY Mode Phase Error: ±3 degrees
Support the sampling rate : 5KSa/s~200MSa/s (in a 1-2-5 sequence)
Persist Off, 1sec, 2sec, 5sec, Infinite
Display Model Main, Window, Window Zoom, Roll, X-Y
Menu Display 2Sec, 5Sec, 10Sec, 20Sec, Infinite
Skin Classical, Modern, Tradition, Succinct
Display Language Simplified Chinese, Traditional Chinese, English, Arabic, French, German,
Russian, Spanish, Portuguese, Japanese, Korean
Power Source Voltage 100-240VAC、47HZ-440HZ、50VA Max
Size and Weight 305mm x 154mm x133mm, about2.3kg
USB Host Support USB flash drive storage
USB Device Support PictBridge compatible printers and PC Remote control
RS-232

Hantek DSO3064A PC USB Oscilloscope

Darmatek Alat Ukur dan Instrument

Hantek DSO3064A PC USB Oscilloscope
60MHz bandwidth; 2 or 4 channels oscilloscope; Models with many extra functions like arb. waveform generator, logic analyzer to select; USB 2.0 interface, LAN optional.
 
Overview
Features

  • 8--36V wide range of input voltage, suitable for vehicle power test.    
  • USB 2.0 interface, LAN optional.    
  • More than 20 kinds of automatic measurement function, PASS/FAIL Check function, is suitable for engineering application.
  •  Excellent industrial design,similar interface with bench oscilloscope. Easy to use.
  • Software support: Windows NT, Windows 2000, Windows XO, VISTA, Windows 7.
  • Supply DEMO code(VC, VB, LABIEW) and technical support.


Model
Analog Channels
2
2
2
4
4
Arb. Waveform Generator
Yes
No
Yes
Yes
No
Logic Analyzer
Yes
Yes
No
No
No
Parameters

Model DSO3062AL DSO3062L DSO3062A DSO3064A DSO3064
VERTICAL
Analog Channels 2 2 2 4 4
Bandwidth 60MHz 60MHz 60MHz 60MHz 60MHz
Rise Time 5.8ns 5.8ns 5.8ns 5.8ns 5.8ns
Input Impedance Resistance: 1MΩ; Capacitance: 25 pF
Input Sensitivity 10mV/div to 5V/div
Input Coupling AC/DC/GND
Vertical Resolution 8 bits
Memory Depth 10K-16M/CH
Maximum Input 400V (DC+AC Peak)
HORIZONTAL
Real-Time Sampling Rate 200MS/s 200MS/s 200MS/s 200MS/s 200MS/s
Time Base Range 5ns/div to 1000s/div(1-2-5 sequences)
Time Base Precision ±50ppm
TRIGGER
Source CH1, CH2,EXT,D0-D15 CH1, CH2,EXT CH1, CH2,CH3,CH4,EXT
Mode Edge,Pulse,Video,Alternative
Auto Measurement Vpp, Vamp, Vmax, Vmin, Vtop, Vmid, Vbase, Vavg, Vrms, Vcrms, Preshoot, Overshoot, Frequency, Period, Rise Time, Fall Time, Positive Width, Negative Width, Duty Cycle
Cursors Measurement Cross, Trace, Horizontal, Vertical
Waveform Signal Process +,- , x,÷, FFT, Invert
Voltage Range 10mV to 5V/div @ x 1 probe; 100mV to 50V/div @ x 10 probe;
1V to 500V/div @ x 100 probe; 10V to 5000V/div @ x 1000 probe; 
100V to 50000V/div @ x 10000 probe;  200mV to 100V/div @ 20:1
Current Range CC65(20A),CC65(60A),CC650,CC1100
FFT Rectangular, Hanning, Hamming, Blackman Window
Math Adition, subtraction, multiplication, division
Logic Analyzer
High input impendence 200K(C=10p) -- -- --
Input Voltage range  -60V~60V  -- -- --
Logic threshold range  -6~6V  -- -- --
Max Sample Rate 100MHz -- -- --
Bandwidth 10MHz -- -- --
Compatible input TTL, LVTTL, CMOS,
 LVCMOS,ECL, PECL, EIA
-- -- --
Storage depth 10K-16M/CH -- -- --
Arbitrary Waveform Generator Mode
Waveform Frequency DC~25MHz -- DC~25MHz --
DAC 2K~200MHz adjustable -- 2K~200MHz adjustable --
Frequency Resolution 0.10% -- 0.10% --
Channel 1CH -- 1CH waveform output --
Waveform Depth 4KSa -- 4KSa --
Vertical Resolution 12 bit -- 12 bit --
Frequency Stability <30ppm -- <30ppm --
Wave Amplitude ±3.5V Max. -- ±3.5V Max. --
Output Impedance 50 Ω -- 50 Ω --
Output Current 50mA -- 50mA Ipeak=50mA --
System BW 25M -- 25M --
Harmonic Distortion -50dBc(1KHz),
-40dBc(10KHz)
-- -50dBc(1KHz),  -40dBc(10KHz) --
INTERFACE USB  2.0 (Lan Optional)
POWER SOURCE 8--36V Wide range of input voltage, suitable 
Volume 255 x 190 x 45 (mm)
Weight 1Kg

DEKKO OS-7328 Analog Oscilloscope

Darmatek Alat Ukur dan Instrument

DEKKO OS-7328 Analog Oscilloscope

Specification :
  • Dual channel 20MHz
  • 10 times sweep magnification
  • TV synchronization; X-Y mode
  • High illumination internal graticule CRT
  • Encoded switch, reliable and durable
  • Fully sealed durable attenuation switch
  • ALT triggering function
  • Made in Korea

Hantek DSO2090 PC USB Oscilloscope

Darmatek Alat Ukur dan Instrument

Hantek DSO2090 PC USB Oscilloscope
200MHz bandwidth, 50GSa/s sampling
Overview
  • USB2.0 interface, no external power source required, easy to use.
  • be suitable for notebook computer,product line maintenance,be used easily on business.
  • Dimensions (mm):190(L) x100(W) x35(H), be carried easily.
  • High performance,250MS/s real-time sampling, 200MHz Bandwidth.
  • Operating System: Windows7,Windows Me, Windows NT, Windows 2000, Windows XP ,VISTA,Win8
  • 23 measurement functions, PASS/FAIL Check, be suitable for technical application.
  • Waveform average, persistence, intensity, invert, addition, subtraction, multiplication, division, X-Y plot.
  • Save waveform in the following: text file, jpg/bmp graphic file, MS excel/word file.
  • FFT
  • One computer can connect many DSO, extend channel easily.
  • Labview\VB\VC\Delphi\C++Builder Second Design instance.
Parameters

Model DSO2090 DSO2150 DSO2250 DSO5200 DSO5200A
Channel 2 2 2 2 2
Bandwidth 40MHz 60MHz 100MHz 200MHz 200MHz
Max. Sample rate 100MS/s 150MS/s 250MS/s 200MS/s 250MS/s
Rising Time 8.8ns 5.8ns 3.5ns 1.7ns 1.7ns
Impedance 1MΩ 25pF
Coupling AC/DC/GND
Vertical resolution 8Bit 9 Bit
Gain range 10mV-10V, 10Steps
DC accuracy ±3%
Timebase range 2ns-1h, 39 Steps
Vertical adjustable Yes
Input protection Diode clamping
X-Y Yes
EXT. input Yes
Trigger Mode Auto, Normal and Single
Trigger Slope +/-
Trigger level adjustable Yes
Trigger Type Rising edge, falling edge
Trigger Source CH1, CH2, EXT
Pre/Post trigger 0-100%
Buffer size 64K 64K 1M 64K 1M
Sampling selection Yes
Waveform Display port/line, waveform average, persistence, intensity
Network Open/Close
Vertical mode CH1, CH2, Dual, ADD
Cursor measurement Yes
Math FFT, addition, subtraction, multiplication, division.
Cursor Frequency, Voltage
Accessories S/W CD, probes, manual, USB cord

Hantek DSO5202P Digital Oscilloscope

Darmatek Alat Ukur dan Instrument

Hantek DSO5202P Digital Oscilloscope
Bandwidth:70-200MHz; 1GSa/s Real Time Sample Rate; Record length up to 40K; Multiple automatic measurements; Large (7.0-inch) color display, WVGA(800x480); Trigger mode: edge/pulse width/line selectable video/slop/overtime etc.
Overview
Feature:
  • 200/100/70MHz bandwidths
  • 1GSa/s Real Time sample rate
  • Large (7.0-inch) color display, WVGA(800x480)
  • Record length up to 40K
  • Trigger mode: edge/pulse width/line selectable video/slop/overtime etc.
  • USB host and device connectivity, standard
  • Multiple automatic measurements
  • Four math functions, including FFTs standard
  • Provides software for PC real-time analysisUSB 1.1 and 2.0 Compatible
Parameters

Model DSO5202P DSO5102P DSO5072P
Acquisition
Sample Rate Real-Time Sample: 1GS/s
Equivalent Sample: 25GS/s
Acquisition Modes
Normal Normal data only
Peak Detect High-frequency and randon glith capture
Average Wavefom Average, selectable 4,8,16,32,64,128
Inputs
Inputs Coupling AC, DC, GND
Inpits Impendance 1MΩ±2% ‖20pF±3pF
Probe Attenuation 1X, 10X
Supported Probe Attenuation Factor 1X, 10X, 100X, 1000X
Maximum Input Voltage CAT I and CAT II: 300VRMS (10×), Installation Category;
CAT III: 150VRMS (1×);
Installation Category II: derate at 20dB/decade above 100kHz to 13V peak AC at 3MHz* and above. For non-sinusoidal waveforms, peak value must be less than 450V. Excursion above 300V should be of less than 100ms duration. RMS signal level including all DC components removed through AC coupling must be limited to 300V. If these values are exceeded, damage to the oscilloscope may occur.
Horizontal
Sample Rate Range 500MS/s--1GS/s
Waveform Interpolation (sin x)/x
Record Length 40K
SEC/DIV Range 2ns/div to 40s/div 4ns/div to 40s/div
Sample Rate and
Delay Time Accuracy
±50ppm(at over any ≥1ms time interval)
Position Range 2ns/div to 10ns/div; 
(-4div x s/div) to 20ms;
20ns/div to 80us/div; (-8div x s/div) to 40ms;
200us/div to 40s/div; (-8div x s/div) to 400s
Delta Time Measurement Accuracy 
(Full Bandwidth)
Single-shot, Normal mode:± (1 sample interval +100ppm × reading + 0.6ns);
>16 averages:± (1 sample interval + 100ppm × reading + 0.4ns);
Sample interval = s/div ÷ 200
Vertical
Vertical Resolution 8-bit resolution, all channel sampled simultaneously
Position Range 2mV/div to 200mV/div, ±2V
200mV/div to 5V/div, ±50V
Bandwidth 200MHz 100MHz 70MHz
Rise Time at BNC( typical) 1.8ns  3.5ns 5ns
Analog Bandwidth in Normal and Average modes at BNC or with probe, DC Coupled 2mV/div to 20mV/div, ±400mV;  50mV/div to 200mV/div, ±2V
500mV/div to 2V/div, ±40V; 5V/div, ±50V
Math +, -, *, /, FFT
FFT Windows: Hanning, Flatop, Rectamgular, Bartlett, Blackman;
1024 sample point
Bandwidth Limit 20MHz
Low Frequency Response (-3db) ≤10Hz at BNC
DC Gain Accuracy ±3% for Normal or Average acquisition mode, 5V/div to 10mV/div;
±4% for Normal or Average acquisition mode, 5mV/div to 2mV/div
DC Measurement Accuracy, 
Average Acquisition Mode
When vertical displacement is zero, and N ≥16:± (3% × reading + 0.1div + 1mV) only 10mV/div or greater is selected; 
When vertical displacement is not zero, and N≥16: ± [3% × (reading + vertical position) + 1% of vertical position + 0.2div]; Add 2mV for settings from 2mV/div to 200mV/div; add 50mV for settings from 200mV/div to 5V/div
Volts Measurement Repeatability, 
Average Acquisition Mode
Delta volts between any two averages of ≥16 waveforms acquired under same setup and ambient conditions
Trigger System
Trigger Types Edge, Video, Pulse, Slope, Over time, Alternative
Trigger Source CH1, CH2, EXT, EXT/5, AC Line
Trigger Modes Auto, Normal, Single
Coupling Type DC, AC, Noise Reject, HF Reject, LF Reject
Trigger Sensitivity
(Edge Trigger Type)
DC(CH1,CH2):
1div from DC to 10MHz; 1.5div from 10MHz to 100MHz; 2div from 100MHz to Full;
DC(EXT): 
200mV from DC to 100MHz; 350mV from 100MHz to 200MHz;
DC(EXT/5):       
1V from DC to 100MHz;1.75V from 100MHz to 200MHz;       
AC: Attenuates signals below 10Hz;
HF Reject: Attenuates signals above 80kHz; 
LF Reject: Same as the DC-coupled limits for frequencies above 150kHz; attenuates signals below 150kHz
Trigger Level Range CH1/CH2: ±8 divisions from center of screen; 
EXT: ±1.2V;
EXT/5:±6V
Trigger Level Accuracy( typical)Accuracy is for signals having rise and fall times ≥20ns CH1/CH2: 0.2div × volts/div within ±4 divisions from center of screen;
EXT: ± (6% of setting + 40mV);
EXT/5: ± (6% of setting + 200mV);
Set Level to 50%(typical) Operates with input signals ≥50Hz
Video Trigger
Video Trigger Type  CH1, CH2: Peak-to-peak amplitude of 2 divisions;
EXT: 400mV;
EXT/5: 2V
Signal Formats and Field Rates, Video Trigger Type Supports NTSC, PAL and SECAM broadcast systems for any field or any line
Holdoff Range 100ns ~ 10s
Pulse Width Trigger
Pulse Width Trigger Mode Trigger when (< , >, = , or ≠); Positive pulse or Negative pulse
Pulse Width Trigger Point Equal: The oscilloscope triggers when the trailing edge of the pulse crosses the trigger level.
Not Equal: If the pulse is narrower than the specified width, the trigger point is the trailing edge. Otherwise, the oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width.
Less than: The trigger point is the trailing edge.
Greater than (also called overtime trigger): The oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width
Pulse Width Range 20ns ~ 10s
Slope Trigger
Slope Trigger Mode Trigger when (< , > , = , or ≠ ); Positive slope or Negative slope
Slope Trigger Point Equal: The oscilloscope triggers when the waveform slope is equal to the set slope.
Not Equal: The oscilloscope triggers when the waveform slope is not equal to the set slope.
Less than: The oscilloscope triggers when the waveform slope is less than the set slope.
Greater than: The oscilloscope triggers when the waveform slope is greater than the set slope.
Time Range 20ns ~ 10s
Overtime Trigger
Over Time Mode Rising edge or Falling edge
Time Range 20ns ~ 10s
Alternative Trigger
Trigger on CH1 Internal Trigger: Edge, Pulse Width, Video, Slope
Trigger on CH2 Internal Trigger: Edge, Pulse Width, Video, Slope
Trigger Frequency Counter
Readout Resolution 6 digits
Accuracy (typical) ±30ppm (including all frequency reference errors and ±1 count errors)
Frequency Range AC coupled, from 4Hz minimum to rated bandwidth
Signal Source Pulse Width or Edge Trigger modes: all available trigger sources
The Frequency Counter measures trigger source at all times, including when the oscilloscope acquisition pauses due to changes in the run status, or acquisition of a single shot event has completed.
Pulse Width Trigger mode: The oscilloscope counts pulses of significant magnitude inside the 1s measurement window that qualify as triggerable events, such as narrow pulses in a PWM pulse train if set to < mode and the width is set to a relatively small time.
Edge Trigger mode: The oscilloscope counts all edges of sufficient magnitude and correct polarity.
Video Trigger mode: The Frequency Counter does not work.
Measure
Cursor Measurement Voltage difference between cursors: △V
Time difference between cursors: △T
Reciprocal of △T in Hertz (1/ΔT)
Auto Measuerment Frequency, Period, Mean, Pk-Pk, Cycli RMS, Minimum, Maximum, Rise time, Fall Time, +Pulse Width, -Pulse Width, Delay1-2Rise, Delay1-2Fall, +Duty, -Duty, Vbase, Vtop, Vmid, Vamp, Overshoot, Preshoot, Preiod Mean, Preiod RMS, FOVShoot, RPREShoot, BWIDTH, FRF, FFR, LRR, LRF, LFR, LFF
Display
Display Type 7 inch 64K color TFT (diagonal liquid crystal)
Display Resolution 800 horizontal by 480 vertical pixels
Display Contrast Adjustable (16 gears) with the progress bar
Probe Compensator Output
Output Voltage( typical) About 5Vpp into ≥1MΩ load
Frequency(typical) 1kHz
Power Supply
Supply Voltage 100-120VACRMS(±10%), 45Hz to 440Hz, CATⅡ
120-240VACRMS(±10%), 45Hz to 66Hz, CATⅡ
Power Consumption <30W
Fuse 2A, T rating, 250V
Environmental
Temperature Operating: 32℉ to 122℉ (0℃ to 50℃);
Nonoperating: -40℉ to 159.8℉ (-40℃ to +71℃)
Cooling Method Convection
Humidity +104℉ or below (+40℃ or below): ≤90% relative humidity;
106℉ to 122℉ (+41℃ to 50℃): ≤60% relative humidity
Altitude Operating: Below 3,000m (10,000 feet);
Nonoperaring: Below 15,000m(50,000 feet)
Mechanical
Size Length 385mm, Width 200mm, Height 245mm
Weight 3.5KG(with Packing);  2.08KG(without Packing)