Senin, 25 April 2016

VOM VOS-6100 CRT Readout Analog Oscilloscope

Darmatek Alat Ukur dan Instrument

VOM VOS-6100 CRT Readout Analog Oscilloscope

Features
  1. 100MHz Bandwidth, Dual Channel, Delayed Sweep
  2. Built-In 6 Digit Universal Counter
  3. 10 Sets Memory for Front Panel Setting Save Recall
  4. Time Base Auto-Range
  5. Cursor Readout with 7 Measurement
  6. Panel Setup Lock of Digital-Control Functions
  7. Buzzer Alarm
  8. LED Indicator
  9. TV Synchonization
  10. Trigger Signal Output
  11. Z-Axis Modulation Input
  12. SMD Technology, High Stability and Reliability

Specification
Cursor Measurement
  • Cursor Measurement Function : T, 1/ T, V; P ( t, v)
  • Cursor Readout Function
  • Cursor Resolution : 1 / 25 DIV
  • Effective Cursor Range Vertical : V/ DIV, AC/ DC/ GND, CH1, CH2, INV, ALT, CHOP, ADD; Horizontal : TIME? DIV, x1/ x10) , X-Y
Horizontal System
  • Horizontal Modes : MAN ( A) , ALT, DELAY ( B)
  • A ( main) Sweep Time : 50nS ~ 0.5S/ DIV, continuously variable ( UNCAL)
  • B ( delay) Sweep Time : 50nS ~ 50mS/ DIV
  • Accuracy : ± 3 % ( ± 5 % at x 10MAG)
  • Sweep Magnification : x10 ( maximum sweep time 5nS/ DIV)
  • Hold OFF Time : Variable
  • Delay Time : 1µ S ~ 5S
  • Delay Jitter : 1/ 20000 or less
  • Alternate Separation : Variable
X-Y Mode
  • Sensitivity : X-axis, Y-axis selectable
  • X-Axis : CH1, CH2 ’ 2mV ~ 5V/ DIV ± 3%
  • Y-Axis : CH1, CH2 ’ 2mV ~ 5V/ DIV ± 3%
  • EXT ’ 0.1V/ DIV ± 5%
  • X-Axis Bandwidth : DC ~ 500KHz ( -3dB)
  • Phase Error : 3° or less at DC ~ 50KHz
Cursor Readout Function
  • Cursor Resolution : 1/ 100DIV
  • Effective Cursor Range : Vertical : ± 3DIV, Horizontal : ± 4DIV
  • Cursor Measurement Function : V, V% , VdB, T, 1 / T, T% ,
  • Panel Setting :
    • Vertical : V/ DIV ( CH1, CH2) , UNCAL, ADD, INV, P10, AC/ DC/ GND
    • Horizontal : S/ DIV ( MTB, DTB) , UNCALx 10, Delay time Hold-off
    • Trigger : Source, Coupling, Slope, Level, TV-H
    • Others : X-Y, LOCK, SAVE / RECALL, MEM 0-9
CRT
  • Type : 6-inch rectangular type with internal graticule 0% , 10% , 90% and 100% markers. 8x10DIV ( 1 DIV = 1 cm)
  • Phosphor : P31
  • Accelating Potensial : 16KV approx
  • Illumination : Continuous adjustable
Vertical Deflection System
  • Sensitivity : 2mV ~ 5V/ DIV, 11 step in 1-2-5 sequence
  • Sensitivity Accuracy : 3% ( 5DIV : at the center display)
  • Vernier Vertical Sensitivity : Continuosly variable to 1 / 2.5 or less than panel-indicated value
  • Frequency Bandwidth ( -3dB) : DC ~ 100MHz ( 2mV/ DIV : DC ~ 20MHz)
  • Rise Time : 3.5ns ( 2mV/ DIV : 17.5ns)
  • Signal Delay : Leading edge can be monitored
  • Maximum Input Voltage : 400V ( DC + AC) at 1KHz or less
  • Input Impedance : 1M& ± 2% / / 25pF approx
  • Vertical Modes : CH1, CH2, DUAL ( CHOP / ALT) , ADD ( DIFF mode can be established when the CH2 is in the INV mode)
  • CHOP Repetition Frequency : Approx. 250KHz
  • Polarity ( INV) : CH2 only
  • Bandwidth Limited : 20MHz
  • Common-mode Rejection Ration : 50: 1 or better at 50KHz
Trigger System
  • Trigger Modes : AUTO, NORM, TV
  • Trigger Source : CH1, CH2, LINE, EXT
  • Trigger Couplig : AC, DC, HFR, LFR
  • Trigger Slope : + / - polarity or TV sync polarity
  • Trigger Sensitivity :
    • AUTO : 10Hz ~ 20MHz, 0.35DIV, 50mVpp ( 20MHz ~ 100MHz) 1.5DIV, 150mVpp
    • NORM : DC ~ 20MHz, 0.35DIV, 50mVpp ( 20MHz ~ 100MHz) 1.5DIV, 150mVpp
    • TV : Sync signal, 1DIV, 200mVpp
    • Trigger Level Range :
      • INT : ± 4DIV or more
      • EXT : ± 0.4DIV or more
      • TV Sync : TV-V, TV-H
      • Max. External Inout Voltage : 400V ( DC + AC peak) at 1KHz
      • External Input Impedance : 1M& ± 5% // 25pF approx
Z-Axis Input
  • External intensity modulation
  • Coupling : DC
  • Voltage : 5V or more
  • Maximum Input Voltage : 30V ( DC + AC peak) at 1KHz or less
  • Bandwidth : DC ~ 5MHz
Trigger Signal Output
  • Voltage : 25mV/ DIV approx. in 50& termination
  • Frequency Response : DC ~ 10MHz
  • Output Impedance : 50& approx
Calibration Output
  • Waveform : 1KHz ± 5% , square wave
  • Voltage : 2Vpp ± 2%
  • Impedance : 2k& approx
Special Function
  • TIME / DIV Auto Range ( MOS-6103 / 6061 / 6060) : Provided
  • Panel Setting Save Recall ( MOS-6103 / 6061 / 6060) : 10 set
  • Panel Setups Lock : Provided

0 komentar: