Rabu, 13 April 2016

Dekko KY-4105A Earth Resistance Meter


Spesifikasi Dekko Model KY-4105A :
- Earth Voltage : 0 ~ 30V ± ( 3% + 5 )
- Earth Resistance : 20/ 200/ 2000 Ohm ± ( 2% + 3)
- Resolution : 0.01W
- Data Hold : Yes
- Working LED Indicator : Yes
- Function Symbol Display : Yes
- Low Battery Check : Yes
- Dimension : 150 x 100 x 70 mm
- Weight : approx.680g
- Power Source : AA 1.5V x 6 ( UM 3) 12V x 1

Dekko KY4102A Earth Resistance Tester


Earth Resistance Meter

Spesifikasi Model KY-4102A
- Earth Voltage : 0 ~ 30V ± 5%
- Earth Resistance : 20/ 200/ 2000 Ohm ± 5 %
- Low Battery Check : Yes
- Dimension : 150 x 100 x 70 mm
- Weight : approx.680g
- Power Source : AA 1.5V x 6 ( UM 3) 12V x 1

Kitamoto 4105A Earth Grounding tester

Full-featured, high accuracy, convenient and reliable operation, the structure of moisture-proof dustproof, more suitable for field use. It can be used to measure various power systems, electrical equipment, lightning protection equipment grounding resistance value of the grounding system, also can measure AC voltage

basic functions
measuring mode

the distance

resolution

basic accuracy

ground resistance

20 ©

0: 01 ©

± ( 2% + 0.1 © )

200 ©

0.1 ©

± ( 2% + 3dgt)

2000 ©

1 ©

Ground current ( AC current)

200V

0.1V

± ( 2, 0% + 6dgt)

Common features

exhibition

Screen 84, 8 × 59.8mm LCD, max screen " 1999 " .

Over the span of presentation

it will display " 1 " on the number above if long range

power

LR alkalescence battery ( 1.5V) × 8 ( can contact with power adapter) when the battery is low, it will show signs of low battery

Dissipation

The cost of electricity during the test < = 800mW

work environment

Teperature 0-40; relative humidity 30% -80% RH

product size

175 ( L) x 110 ( W) x 70 ( D) mm

weight

Approximately: 680g ( including battery)

Fluke 1621 Ground Tester


Fluke 1621 Ground Tester
WITH A SIMPLE USER INTERFACE AND INTUITIVE FUNCTIONALITY, THE FLUKE 1621 IS AN EASY-TO-USE EARTH GROUND TESTER

INSTRUMENT FEATURES
The Fluke 1621 features basic ground testing methods including 3-pole Fall of Potential and 2-pole ground resistance, and enables users to capture values with a single button, making it a handy tool for electrical contractors, utility test engineers and earth ground specialists in the field.
The Fluke 1621 has automatic noise voltage detection to help ensure accurate measurements, and will alert users to measurements outside of an adjustable limit setting.
With a simple user interface and intuitive functionality, the Fluke 1621 is a handy grounding tool for electrical contractors, utility test engineers, and earth ground specialists

Fluke 1621 Ground Tester Features
3-pole Fall-of-Potential earth testing.
2-pole resistance measurements.
Easily capture values with single-button operation.
Automatic 'noise' voltage detection.
Measuring rate 2 measurements/second.
Hazardous voltage warning.
Clearly read and record data with a large, backlit display.
Safety: IEC/EN 61010-1, 600 V CAT II, pollution degree 2.
Dimensions: 113 x 54 x 216mm (inc. holster).
Weight: 850 g (1.9 lb).

Included Accessories:
Fluke 1621 Users manual, 2 measuring leads with alligator clips, 2m (6 ft), battery, 9 V alkaline (LR61), protective holster, Fluke 1621 CD-ROM.

Fluke 1625-2 Advanced GEO Earth Tester Kit



Fluke 1625-2 Advanced GEO Earth Tester Kit
FOR EACH TEST, THE TESTERS INFORM YOU WHICH STAKES OR CLAMPS NEED TO BE CONNECTED AND THE LARGE ROTARY SWITCH CAN BE USED EVEN WITH A GLOVED HAND

INSTRUMENT FEATURES
The Fluke 1625-2 earth ground tester is able to measure earth ground loop resistances using only clamps. With this test method, two clamps are placed around the earth ground rod and each are connected to the tester. No earth ground stakes are used at all. A known, fixed voltage is induced by one clamp and the current is measured using the second clamp. Then the tester automatically determines the resistance of the earth ground rod.
With Stakeless testing, the earth ground rod does not need to be disconnected - leaving the bonded earth ground system intact during test. Gone are the days of spending time placing and connecting stakes for each earth ground rod on your system - a major time saver. You can also perform earth ground tests in places you’ve not considered before: inside buildings, power pylons, or anywhere you don’t have access to soil.

Fluke 1625-2 GEO Earth Tester Kit Features
Automatic Frequency Control (AFC): Identifies existing interference.
R* measurement: Calculates earth ground impedance at 55 Hz.
Adjustable limits: For quicker testing.
3 and 4 Pole Fall-of-Potential (using stakes).
4-Pole Soil Resistivity Testing (using stakes).
Selective Testing (using 1 clamp and stakes).
Stakeless Testing (using 2 clamps only).
Display: 1999 digit LCD.
Operating temperature: -10°C to 50°C (14°F to 122°F).
Memory: Internal memory storage up to 1500 records accessible via USB port.
Measuring time: Typical 6 sec.
Auxiliary power: 6 x 1.5 V alkaline (type AA LR6).
Battery life span: Typical > 3,000 measurements.
Protective type: IP56 for case, IP40 for battery door according to EN60529.
Dimensions: 250 mm x 133 mm x 187 mm (9.75 in x 5.25 in x 7.35 in).
Weight: 7.6 kg (16.8 lb) incl. accessories and batteries in carrying case.
See PDF datasheet for full specifications.

Included Accessories:
Includes Fluke 1625-2 Users Manual, Safety Information, QRG, Geox Probe, Cable, 2 clips, Lead set, 4 Earth Stakes, 3 Cable Reels, C1620, Carrying Case, EI-162X & EI-162AC.

Fluke 1630 Earth Ground Clamp


Fluke 1630 Earth Ground Clamp
THE RUGGED AND COMPACT DESIGN MAKES THE FLUKE 1630 EASY TO USE IN SMALL PLACES AND HARSH ENVIRONMENTS

INSTRUMENT FEATURES
The Fluke 1630 Earth Ground Clamp is a hand-held battery-operated clamp that measures the ground resistance of a ground rod without using auxiliary ground rods. The 1630 can be used in multi-grounded systems without disconnecting the ground under test.
The Fluke 1630 uses the Stakeless testing method, which eliminates the need to disconnect parallel ground rods and find suitable locations for placing auxiliary ground stakes. This saves time and enables users such as industrial and utility electricians, and field service electricians and contractors, to perform earth ground loop tests in locations where it is not possible to use other techniques, including inside buildings or on power pylons. The Clamp can be used in the following applications: Earth resistance testing of high voltage pylons, buildings, cell phone substations and RF transmitters and the inspection of lightning protection systems.

Fluke 1630 Earth Ground Clamp Features
Wide ground loop resistance range.
Display: 9999 digit liquid crystal display with special symbols.
Operating Humidity: Less than 85° RH.
Conductor Size: 35 mm (1.38 in) approximately.
Measurement of ground leakage current, from 0.2mA to 1000mA.
Wide ac current measurement range from 0.2A to 30A.
User-defined HI / LO Alarm limits.
Data Logging Capacity: 116 records.
Data Logging Interval: 1 to 255 seconds.
Overload Indication: OL.
Measurement Frequency: 3.333 kHz.
Power Requirement: 9 V alkaline.
Safety: 300 V, CAT III pollution degree 2 IEC 61010-1 and IEC 61010-2-032.
Dimensions: 276 mm (L) x 100 mm (W) x 47 mm (H).
Weight: 750 g (1.65 lbs).

Included Accessories:
Carrying case with strap, Resistance test loop, 9V battery & Fluke 1630 Users manual.

Kyoritsu 4105A Earth Tester - Soft Case


KYORITSU  4105A Earth Tester - Soft Case
Small and lightweight, the Kyoritsu 4105A Soft Case Model comes with a shock resistance case.
  • Dust and drip proof.(designed to IEC 529 IP54)
  • In addition to the facility for precision measurement, test leads for simplified two wire measuring system also supplied as standard accessories.
  • (unit can be hung from the neck for simplified measurement)
  • Designed to meet IEC 61010-1 safety standard.
  • Capable of measuring earth voltage.
  • Automatic warning when resistance of auxiliary earth spikes is in excess of tolerance.
  • 2mA measuring current permits earth resistance tests without tripping earth leakage current breakers in the circuit under test.
Specification:
Measurement Ranges
  • Earth Resistance: 0~20Ω/0~200Ω/0~2000Ω
  • Earth Voltage [50,60Hz]: 0~200V AC
Accuracy
  • Earth Resistance: ±2%rdg±0.1Ω (20Ωrange)
  • ±2%rdg±3dgt (200Ω/2000Ωrange)
  • Earth Voltage: ±1%rdg±4dgt
Overload Protection
  • Earth Resistance: 280V AC for 10 seconds across 2 of the 3 terminals
  • Earth Voltage: 300V AC for 1 minute
Safety Standard
  • IEC 61010-1 CAT.III 300V Pollution Degree 2, IEC 61557
Applicable Standards IEC 60529 IP54 Withstand Voltage 3700V AC for 1 minute Power Source R6P (AA) (1.5V) × 6 Dimensions 105(L) × 158(W) × 70(D)mm Weight 550g approx.
Accessories
  • 7095A (Earth resistance test leads) × 1set
  • (red-20m, yellow-10m, green-5m)
  • 8032 (Auxiliary earth spikes) × 1set
  • 7127A (Simplified measurement probe) × 1set
  • R6P (AA) × 6
  • Neck strap
  • Instruction Manual
  • Carrying Case : 4105A (Soft case)/4105A-H (Hard case)
Optional 7100 (Precision measurement cord set)

Kyoritsu 4106 Earth Resistance & Resistivity Tester


KYORITSU 4106 Earth Resistance & Resistivity Tester
  • High test current up to 80mA yielding resolution of 0.001Ω on 2Ω range.
  • Advanced Filtering method (based on FFT Fast Fourier Transform) reduces noise interference for obtaining stable measurements.
  • Automatic and Manual selection of the Test Current Frequency in four bands (94/105/111/128Hz). In Automatic mode, KEW 4106 will select the most suitable Frequency.
  • Several sub-results can be shown on the display: Resistance of the Auxiliary Earth Spikes, Frequency of Test Current, Voltage and Frequency of Interference (noise), Residual Resistance Rk, etc.
  • Warning for excessive noise and high Auxiliary Earth Spikes resistance.
  • Large Graphic Display with backlight for readings in poorly illuminated areas.
  • Up to 800 measurement results can be saved in the memory and recalled on the display.
  • The stored results can be transferred to a PC using the "KEW Report" software and a USB adaptor (Model 8212-USB) which are included.
  • Robust design with IP54 protection.

Function
Range
Resolution
Measuring range
Accuracy
Earth resistance
Re
(Rg at
ρ measurement)
2Ω
0.001Ω
0.03~2.099Ω
|±2%rdg±0.03Ω
20Ω
0.01Ω
0.03~20.99Ω
|±2%rdg±5dgt (*1)
200Ω
0.1Ω
0.3~209.9Ω
2000Ω
1Ω
3~2099Ω
20kΩ
10Ω
0.03~20.99kΩ
200kΩ
100Ω
3~209.9kΩ
Auxiliary earth resistance
Rh, Rs



8% of Re+Rh+Rs
Earth resistivity
ρ
2Ω
0.1Ω•m~1Ω•m
Autoranging
0.2~395.6Ω•m
ρ=2×π×a×Rg (*2)
20Ω
0.2~3956Ω•m
200Ω
20~39.56kΩ•m
2000Ω
0.2~395.6kΩ•m
20kΩ
2.0~1999kΩ•m
200kΩ
Series interference voltage
Ust (A.C only) (*3)
50V
0.1V
0~50.9Vrms
|±2%rdg±2dgt (50/60Hz)
|±3%rdg±2dgt (40~500Hz)
Frequency
Fst
Autoranging
0.1Hz
1Hz
40Hz~500Hz
|±1%rdg±2dgt
Measuring method
Earth resistance: Fall-of-potential method (currents and voltages measured via the Probes)
Measurement method of Earth Resistivity (ρ): Wenner 4-pole method
Series interference voltage (earth voltage): RMS Rectifier (between the E-S Terminals)
Memory capacity
800 data
Communication Interface
Model 8212-USB Optical Adaptor
LCD
Dot-matrix 192×64 monochrome
Over-range Indication
"OL"
Overload Protection
between E-S(P) and between E-H(C) terminals AC280V / 10 sec.
Withstand voltage
between the electrical circuit and enclosure AC3540V(50/60Hz) / 5 sec.
Applicable standards
IEC 61010-1 CAT.III 300V, CAT.IV 150V Pollution degree 2
IEC 61010-031, IEC 61557-1, 5, IEC 61326-1 (EMC), IEC 60529 (IP54)
Power source
DC12V : sizeAA manganese dry battery (R6P) × 8
(Auto power off: approx. 5 minutes)
Dimensions
167(L) × 185(W) × 89(D) mm
Weight
approx. 900g (including batteries)
Accessories
7229A (Earth precision measurement),
7238A (Simplified measurement test leads),
8032 (Auxiliary earth spikes [2 spiks/set])×2 sets (4 spikes in total),
8200-04 (Cord reel [4 pcs])×1 set,
8212-USB (USB adaptor with "KEW Report(Software)"),
9121 (Shoulder strap),
9125 (Carrying case),
R6P×8, Instruction manual, Calibration certificate
Optional
8212-RS232C (RS232C adaptor with "KEW Report(Software)")
(*1) Auxiliary earth resistance is 100Ω with Rk correction
(*2) Depending on the measured Rg. Interval [a] between auxiliary earth spikes is 1.0~30.0m
(*3) This instrument is NOT designed to measure line voltages on commercial powers.

Constant 25ER Analog Earth Tester


CONSTANT 25ER Analog Earth Tester

Features
  • Operate With The Minimum Of Influence From Earth Voltage And Earth Resistance Of Auxiliary Earth Bars
  • Simplified Earth Resistance Measurement Method
  • Self-Check Facility For Checking Battery And Lead Wire Connection
  • Push Switch Buttons For Smooth Operation Of The Instrument
  • Withstand Voltage (1500VAC) For One Minute Between Electrical Circuit And Housing Case

Function
Range
Accuracy
Earth Resistance
10/100/1000Ω
±5% of full scale reading
Earth Voltage
30VAC (5kΩ/V)
±5% of full scale reading
Battery
8 x 1.5V (AA size)
Size / Weight
H140 x W140 x D90mm / Approx. 800g
Standard Accessories
Test Leads (5m, 10m, 15m), Auxiliary Earth Bars, Water Resistant Hard Case, Battery, Manual

Extech 382252 Earth Ground Resistance Tester



Extech 382252 Earth Ground Resistance Tester
  • Comes complete with test leads and two auxiliary Earth bars
  • AC/DC voltage, resistance, and continuity testing
  • Auto power off
Details
Consisting of everything you'll need to accurately measure earth ground resistance across 3 ranges up to 2000Ω, this great-value Extech bundle includes a tester, earth bars, carrying case and more!
The meter included with this kit is the Extech 382252, an earth ground resistance tester shaped like a multimeter that can measure 20Ω, 200Ω and 2000Ω earth resistance with basic accuracy of ±(2%rdg+2d). It can also use AC earth voltage from 0 to 200V AC and includes all necessary testing procedures for accurately determining earth resistance levels.
Measurements are shown on a large-size dual display with integrated backlight for use in poor lighting conditions. A data hold function is also included to temporarily store the last testing value taken on the instrument's screen.

Key Features
  • Measures earth ground resistance from 20 to 2000Ω
  • Large size dual display with integrated backlight for use in poor lighting conditions
  • Automatic zero adjustment
  • Measures AC/DC voltage, resistance and continuity
  • Auto power off when left idle conserves the battery life
  • Overrange and low battery indicators 
What's Included?
  • Extech 382252 Earth Ground Resistance Tester
  • Test Leads
  • 2 x Auxiliary Earth Bars
  • Carrying Case
  • Protective Rubber Holster
  • 6 x 1.5V AA Batteries
Specification
Earth Ground Resistance Ranges
20Ω/ 200Ω/2000Ω
Basic Accuracy
±(2%rdg+2d)
Resolution
0.01Ω/ 0.1Ω/1Ω
Test Current/Frequency
<2.5mA / 820Hz
AC Earth Voltage/Frequency
0 to 200VAC / 50 to 400Hz
Accuracy
±(3%rdg+3d)
DC Voltage
0 to 1000V
Accuracy
±(0.8%rdg+3d)
Resistance
0 to 200kΩ
Accuracy
±(1%rdg+2d)
Continuity
40Ω
Power Supply
Six 1.5V ‘AA’ Batteries
Dimensions
7.9 x 3.6 x 2" (200 x 92 x 50mm)
Weight
1.5lbs (700g) (meter only)

Extech GRT300 4 Wire Earth Ground Resistance Tester


Extech GRT300 4 Wire Earth Ground Resistance Tester
  • Earth resistance measurements up to 2000Ω
  • 2, 3 and 4 wire testing procedures
  • Also measures AC earth voltage
Details
Containing everything you need for carrying out measurements of earth ground resistance, the Extech GRT300 kit is a must-have for any professional and allows testing of earth ground across four resistance ranges of 2Ω, 20Ω, 200Ω and 2000Ω (2kΩ).
Fully autoranging for ease of use and encased in its own protective carrying case, the Extech GRT300 both speeds up testing procedures thanks to automatic range selection and is protected at all times from harm during transportation or usage.
This digital earth tester also includes the ability to carry out 4-wire, 3-wire and 2-wire earth resistance testing procedures, with each lead connection assigned a colour for ease of use (the included leads are also colour coded). Selecting a test procedure  is also easy; just make the connections, press 2P, 3P or 4P or ACV voltage and the tester will do the rest!
As well as standard measurements of earth resistance the GRT300 can also be used to carry out automatic I (current) spike checks, automatic P (potential) spike checks and includes the ability to measure AC earth voltage from 0 to 300V AC.

Key Features
  • 2, 3 and 4 wire testing of earth resistance
  • Measurement range from 2 to 2000Ω (2kΩ)
  • Large dual line LCD makes reading back measurements easy
  • Autoranging - the GRT300 will automatically cycle to the correct range dependant on the measurement taken
  • Automatic checks I (current) and P (potential spikes
  • Test hold function
  • Automatic zero adjustment
  • AC earth voltage measurements from 0 to 300V AC
  • Data hold function temporarily stores last value taken on the screen
  • Overrange and low battery indicators
  • CAT IV 300V and EN 61010-1 compliance
What's Included
  • Extech GRT300 Earth Tester
  • 4 x Test Leads with Alligator Clips (Red, Green, Yellow and Black Leads)
  • Hard Carrying Case
  • 8 x 1.5V AA Batteries

Specification
Earth Ground Resistance Ranges
2Ω, 20Ω, 200Ω, 2000Ω
Basic Accuracy
±(2%rdg+3d)
Resolution
0.01Ω, 0.1Ω, 1Ω, 0.01kΩ
Test Current/Frequency
<2mA / 820Hz
AC Earth Voltage/Frequency
0 to 300VAC / 40 to 500Hz
Accuracy
±(2%+3d)
Power Supply
8 x 1.5V AA Batteries
Dimensions
9.8 x 7.8 x 4.3" (250 x 190 x 110mm)
Weight
3.15lbs (1430g) (batteries included)

HIOKI 3151 Earth HiTester


HIOKI 3151 Earth HiTester
Classic Earth Resistance Tester Using 3-Pole Method
Earthing or grounding of electrical equipment is essential to maintain safety, protecting lives, as well as prevent damage to equipment. The 3151 uses the AC phase differential system to measure earthing resistance, which assures that accurate measurements are unaffected by earth voltage and auxiliary earthing resistance.

Overview
  • Wide measurement range for 0 to 1150 Ω, based on EN standard
  • Switchable measurement frequency to minimize the influence of harmonic earth voltage
  • Semi-dust-proof construction
Specification
Operating system
AC potentiometer method, 3-pole measurement, 2-pole measurement
Note: When using 2-pole method, applies only when the measurement range of 100 Ω (0 to 115 Ω) and 1000 Ω (0 to 1150 Ω)
Measurement range
10 Ω (0 to 11.5 Ω)
100 Ω (0 to 115 Ω)
1000 Ω (0 to 1150 Ω)
Accuracy
±2.5 % f.s.
±2.5 % f.s.
±2.5 % f.s.
Earth voltage
30 V (0 to 30 V), Accuracy: ±3.0 % f.s.
Functions
Switchable testing frequency (575 Hz, or 600 Hz), Auxiliary earthing (P/C pole) resistance check
Power supply
R6P (AA) manganese battery ×6 (Continuous use: 350 times), or LR6 (AA) alkaline battery ×6 (Continuous use: 1100 times) (at 30 sec measurement/ 30 sec pause cycle)
Dimensions and mass
164 mm (6.46 in) W × 119 mm (4.69 in) H × 88 mm (3.46 in) D, 800 g (28.2 oz)
Accessories
Auxiliary Earthing Rod 9214 ×2, Measuring Cable 9215 (Black 5 m (16.41 ft), Yellow 10 m (32.81 ft), Red 20 m (65.62 ft), each one, Cable winder×3), Carrying Case 9393 ×1, Hand strap ×1, R6P (AA) manganese battery ×6, Instruction manual ×1

SEW 2120ER 3 Wire Earth Resistance Tester



SEW 2120 ER 3 Wire Earth Resistance Tester

FEATURES
  • Capable of measuring earth resistance and earth voltage.
  • 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test.
  • The leads are supplied as standard accessories for simplified two-wire measuring system.
  • 0Ω adjustment.
  • Battery operated.
  • Data hold function.
  • Low battery indication.
  • Calibration performed with supplied test leads.
Specification
Measuring ranges
Earth resistance 
 0-20Ω / 0-200Ω / 0-2000Ω
 Earth voltage 
 0-200 Vac(40-500Hz)
Accuracy
Earth resistance  ±(2%rdg+2dgt)
 or ±0.1Ω,  which is greater
 Earth voltage  ±(1%rdg+2dgt)
Earth resistance resolution
0-20Ω : 0.01Ω  
 0-200Ω : 0.1Ω  
 0-2000Ω : 1Ω
Measuring system
Earth Resistance by constant current inverter 820Hz approx. 2mA
Display
3½ digit (2000 counts)
0Ω adjustment
-
Open circuit indication
LED will be unlit
LED will be unlit
“  “symbol appears  on the display
Data hold indication
“  “symbol appears on the display
Over range indication
“1”(MSD)
Dimensions
210(L) × 210(W) × 100(D)mm
Weight (battery included)
Approx. 1395g
Power source
1.5V (AA) × 8
Safety standards
IEC/EN 61010-1 CAT III 200V.
IEC 61557-1 IEC 61557-5
EN 61326-1

SEW 4235ER Earth Resistance & Resistivity Testers


SEW 4235ER Earth Resistance & Resistivity Testers

FEATURES
  • Microprocessor-controlled.
  • Earth resistivity (ρ) test.
  • Earth testing at 20Ω, 200Ω, 2kΩ.
  • Earth voltage measuring : 0-300V AC.
  • Automatic C spike check.
  • Automatic P spike check.
  • 2-Wire test, 3-Wire test, 4-Wire test.
  • LCM display.
  • Auto ranging.
  • Auto power OFF.
  • Data hold.
  • 200 measurement results can be saved in the memory and recalled on the display.
  • Interval between auxiliary earth spikes is 1.0~50.0m.

Specification



Measuring ranges
Earth Resistance
 0-20Ω / 0-200Ω / 0-2kΩ
 Earth Voltage
 0-300.0V AC
 Earth Resistivity (ρ=2 × π × L × R)
 0.06~6.28kΩ.m
 0.62~62.8kΩ.m
 6.28~628kΩ.m
Accuracy
Earth Resistance  ±2%rdg ± 3dgt
Earth Voltage  ±2%rdg ± 3dgt

Earth resistance resolution
0-20Ω : 0.01Ω
0-200Ω : 0.1Ω
0-2kΩ : 1Ω
Measuring system
Earth resistance by constant current
Inverter 820Hz approx. 2mA
Temperature& humidity
Operating: 0°C~40°C ≤80% R.H.
Storage: -10°C~50°C ≤80% R.H.
Weight (battery included)
Approx. 1430g
Power source
1.5V (AA) × 8

Safety standards
EN 61010-1 CAT IV 300V
IEC 61557-1  IEC 61557-5
EN 61326-1

Hioki FT6381 Clamp ON Earth Tester


HIOKI CLAMP ON EARTH TESTER FT6381
Lightweight Ground Clamps with Bluetooth® Data Transfer
The FT6380 and FT6381 measure grounding resistance simply by clamping to multiple-grounded ground wires. No auxiliary grounding rod is needed, and there is no need to disconnect the ground wire from the grounding rod. The compact, low-profile sensor can be used to clamp ground wires with ease, and also provide AC current measurement functionality and can measure currents ranging from leakage current on the order of several mA to load currents of up to 60 A.

Overview
  • Earth resistance measurement for multi-grounded systems
  • Measure leak current with absolute certainty with highly sensitive 0.01 mA resolution (at 20.00 mA range)
  • Measure load current up to 60.0 A range
  • Clamp at the narrowest point
  • Data transfer to Android™ phones using Bluetooth® wireless technology
  • Real time data transfer, automatic report generation on Android™ phone

Specification
(Accuracy guaranteed for 1 year, or opening and closing of the clamp sensor 10,000 times)
Measurement principle
Instrument has two cores for voltage injection and current measurement. From the defined voltage and measured current, the total circuit loop resistance is calculated
Note: For multi grounded systems only. In a multi-grounded system, the larger the number of grounding poles, the more accurate the measured value.
Earthing resistance
0.20 Ω (0.01 Ω resolution) to 1600 Ω (20 Ω resolution), 10 ranges, Zero suppression: Less than 0.02 Ω,
Accuracy: ±1.5 % rdg. ±0.02 Ω
AC Current measurement
20.00 mA (0.01 mA resolution) to 60.0 A (0.1 A resolution), 5 ranges, Zero suppression: Less than 0.05 mA,
Accuracy: ±2.0 % rdg. ±0.05 mA (30 Hz to 400 Hz, True RMS), Crest factor 5.0 or less (for the 60 A range, 1.7 or less)
Max. allowable input
100 A AC continuous, AC 200 A for 2 minutes or shorter (at 50/60 Hz, requires derating at frequency)
Max. rated voltage to earth
600 V AC CAT IV
Memory function
2000 data
Alarm function
For resistance measurement and current measurement, Beeps when measured value is less than or greater than threshold
Other functions
Data hold, Backlight, Filter, Auto power save
Display
Digital LCD, max. 2000 dgt., Display refresh rate: 500 ms (2 times/s)
Waterproof and dustproof
IP40 (EN60529) with clamp sensor closed
Communication interface
Model FT6381 only: Bluetooth® v2.1+EDR, Compatibility for Smartphone / Tablet, Displays measured values on the screen of an Android™ handset via Bluetooth®, Applicable OS: Android™ 2.1 or later
Power supply
LR6 (AA) alkaline battery ×2, Max. rated power: 450 mVA, Continuous use : 35 hr (in-house testing conditions)
Core jaw dia.
φ 32 mm (1.26 in)
Dimensions and mass
73 mm (2.87 in) W × 218 mm (8.58 in) H × 43 mm (1.69 in) D, 620 g (21.9 oz)
Accessories
Carrying case ×1, Resistance check loop (1 Ω, 25 Ω) ×1, Strap ×1, LR06 (AA) alkaline battery ×2, Instruction manual ×1

Countries where the FT6381 wireless operation is supported
In Apr. 2014
Vietnam, Thailand, Indonesia
In June 2013
Mexico
In Jan. 2013
Singapore
In July 2012

Japan, the U.S., Canada, the EU 

Kyoritsu 4300 Simplified Earth Tester


KYORITSU 4300 Simplified Earth Tester
KEW 4300 is simplified earth resistance tester (based on 2-pole method) that can be used for various distribution lines and electrical appliances and it also can measure AC/DC voltage. (As for AC Voltages, true rms values can be obtained.)
  • 200/2000Ω (2 ranges): auto-ranging.
  • Warning buzzer triggered at 100Ω or less.
  • LED lights up when a large earth voltage is detected.
  • Live circuit warning when 30V or higher voltage is detected. (KEW 4300 detects voltage even when measuring resistances.)
  • LED light for illuminating measurement points. (It turns on/off automatically in relation to the ambient brightness.)
  • Small test current (max 2mA) not triggering RCD.

Earth resistance ranges
200.0/2000Ω (Auto ranging)
±3%rdg±5dgt
Voltage ranges
AC: 5.0 ~ 300.0V (45 ~ 65Hz)±1%rdg±4dgt
DC: ±5.0 ~ 300.0V±1%rdg±8dgt
Applicable standards
IEC 61010-1 CAT.III 300V pollution degree 2
IEC 61010-031, 61557-1, -5
IEC 61326-1, 2-2, IEC 60529 (IP40)
Withstand voltage
3540V AC for 5 seconds
(between the electrical circuit and enclosure)
Power source
Size AA alkaline battery × 2pcs
Dimensions
232(L) × 51(W) × 42(D)mm
Weight
220g approx. (including battery)
Accessories
7248 (Test lead with Alligator clip and Flat test probe)
8072 (CAT.II Standard prod)
8253 (CAT.III Standard prod)
8017 (Extension prod long)
9161 (Carrying case)
Instruction manual, LR6 (AA) × 2

SEW 1120 ER Earth Resistance Testers


SEW 1120 ER Earth Resistance Testers

FEATURES
  • Capable of measuring earth resistance and earth voltage.
  • 2mA measuring current permits the testing of earth resistance without tripping earth leakage current  breakers in the circuit under test.
  • The leads are supplied as standard accessories for simplified two-wire measuring system.
  • 0Ω adjustment.
  • Battery operated.
  • Data hold function.
  • Low battery indication.
  • Calibration performed with supplied test leads.
SPECIFICATIONS
Measuring ranges
 Earth resistance  
 0-20Ω / 0-200Ω / 0-2000Ω
 Earth voltage  
 0-200 Vac(40-500Hz)
 Accuracy
 Earth resistance  ±(2%rdg+2dgt) 
 or ±0.1Ω,  which is greater
 Earth voltage  ±(1%rdg+2dgt)
 Earth resistance
 resolution

 0-20Ω : 0.01Ω   
 0-200Ω : 0.1Ω   
 0-2000Ω : 1Ω
 Measuring system
 Earth Resistance by constant 
 current inverter 820Hz approx. 2mA
 Display
 3½ digit (2000 counts)
 0Ω adjustment
 ˇ
 Open circuit 
 indication

 LED will be unlit
 Low battery 
 indication

 “  “symbol appears  on the display
 Data hold 
 indication

 “  “symbol appears on the display
 Over range 
 indication

 “1”(MSD)
 Dimensions
 175(L) × 85(W) × 75(D)mm
 Weight
 (battery included)

 Approx. 600g
 Power source
 1.5V (AA) × 8    
 Safety standards
 IEC/EN 61010-1 CAT III 200V
 IEC 61557-1 IEC 61557-5
 EN 61326-1

Selasa, 12 April 2016

SEW 1805 ER Earth Resistance Testers


SEW 1805ER Earth Resistance Testers

FEATURES
  • High quality Taut Band movement.
  • Capable of measuring earth resistance and earth voltage.
  • 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test.
  • Test leads are supplied as standard accessories for simplified two-wire measuring system.
  • Battery operated.
  • Battery check function.
  • Calibration performed with supplied test leads.
SPECIFICATIONS
Measuring ranges
 Earth resistance  
 0-10Ω / 0-100Ω / 0-1000Ω
 Earth voltage  0-30 Vac (40-500Hz)
 Accuracy
 Earth resistance  ±3% of full scale
 Earth voltage  ±2.5% of full scale
 Measuring system
 Earth resistance by constant current 
 inverter 820Hz, 2mA approx.
 Open circuit 
 indication

 LED will be unlit
 Dimensions
 170(L) × 165(W) × 92(D)mm
 Weight
 (battery included)

 Approx. 1000g
 Power source
 1.5V (AA) × 8 
 Safety standards
 EN 61010-1 CAT III 150V
 EN 61326-1

SEW 1620 ER Earth Resistance Testers


SEW 1620 ER Earth Resistance Testers

FEATURES
  • Microprocesser-controlled.
  • Measures earth resistance in three ranges : 40Ω, 400Ω, 4kΩ.
  • Capable of measuring earth voltage.
  • 3 ¾ digit (4000 counts).
  • LCD backlight display.
  • 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test.
  • Data hold function.
  • Relative function.
  • Auto power-off function.
  • Low battery indication.
  • Calibration performed with supplied test leads.

SPECIFICATIONS
Measuring ranges
 Earth Resistance
 0~40Ω / 0~400Ω / 0~4kΩ
 Earth Voltage
 0~400V (40~500Hz)
 Accuracy
 Earth Resistance  ±(2%rdg+3dgt)
 Earth Voltage  ±(2%rdg+3dgt)
Earth resistance
resolution

 0~40Ω : 0.01Ω
 0~400Ω : 0.1Ω
 0~4kΩ : 1Ω
 Measuring system
 Earth resistance by constant current 
 inverter 820 Hz, 2mA approx.
 Dimensions
 163(L) x 102(W) x 50(D)mm
 Weight
 (battery included)

 Approx. 440g  
 Power source
 1.5V (AA) x 6
 Safety standards
 EN 61010-1 CAT IV 400V
 EN 61326-1
 EN 61557-1
 EN 61557-5

SEW 4120ER Earth Resistance Testers


SEW 4120ER Earth Resistance Testers

FEATURES
  • Capable of measuring earth resistance and earth voltage.
  • 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test.
  • The leads are supplied as standard accessories for simplified two-wire measuring system.
  • Battery operated.
  • Data hold function.
  • Battery test indication.
  • Calibration performed with supplied test leads.

SPECIFICATIONS
Measuring ranges
 Earth resistance 
 0-20Ω / 0-200Ω / 0-2000Ω
 Earth voltage 
 0-200 Vac(40-500Hz)
 Accuracy
 Earth resistance 
 ±(2%rdg+2dgt) at 200/2000Ω
 ±(2%rdg+0.1Ω) at 20Ω
 Earth voltage  ±(1%rdg+2dgt)
 Earth resistance
 resolution
 0-20Ω : 0.01Ω  
 0-200Ω : 0.1Ω  
 0-2000Ω : 1Ω
 Measuring system
 Earth Resistance by constant
 current inverter 820Hz approx. 2mA
 Display
 3½ digit (2000 counts)
 Open circuit 
 indication
 LED will be unlit
 Low battery 
 indication
 “   “symbol appears  on the display
 Data hold 
 indication
 “   “symbol appears on the display
 Over range 
 indication
 “1”(MSD)
 Dimensions
 250(L) × 190(W) × 110(D)mm
 Weight
 (battery included)
 Approx. 1500g
 Power source
 1.5V (AA) × 8 
 Safety standards
 EN 61010-1 CAT III 300V
 IEC 61557-1 IEC 61557-5
 EN 61326-1