Rabu, 20 April 2016

CONSTANT LOOP20 Loop Calibrator

Darmatek Alat Ukur dan Instrument

CONSTANT LOOP20 Loop Calibrator
FEATURES
  • 4-20mA Output
  • Auto Power Off
  • High Accuracy and Rapid Response
  • Step, Ramp, and Auto Output
  • Low Battery Indication
  • Easy To Use
Power Supply : 9V battery (ANSI/NEDA 1604A or IEC 6LR619V alkaline)
Operating Temperature : 0°C ~ 50°C
Operating relative humidity : ≤80% RH
Storage Temperature : ≤-10°C~55°C
Storage Relative Humidity : ≤90% RH
Size : 200x100x40mm (with holster)
Weight : 550g (with holster)
Standard Accessories : manual, industrial test lead (with alligator clips attached to probes)
Optional Accessories : AC power-supply adapter

Specification
Output
Measuring
Range
Output Range (mA)
Resolution
Accuracy
Remark
Current
20mA
0.000 ~ 22.000
0.001mA
±0.05% of set
value or ±4µA
Max. 1KΩ at 20mA
(see manual for detail)
Simulation of Transmitter
-20mA
0.000 ~ 22.000
0.001mA
±0.05% of set
value or ±4µA
Max. 1KΩ at 20mA
(see manual for detail)
Loop Power
24V
-
-
±4%
Max. output current up to 25mA

Input
Range
Input Range
Resolution
Accuracy
Remark
Voltage
28V
-0.200 ~ 28.000V
1mV
±0.02% of reading
or ±2mV
Input resistance 2MΩ
Current
20mA
-1.000 ~ 22.000mA
0.001mA
±0.02% of reading
or ±4µA
Input resistance 10Ω
Loop
20mA
0.000 ~ 22.000mA
0.001mA
±0.02% of reading
or ±4µA
Providing 24V loop
power