Selasa, 12 April 2016

Kyoritsu 4200 Earth Clamp Tester


KYORITSU 4200 Earth Clamp Tester
  • The earth resistance from 0.05 to 1500Ω can be measured without the auxiliary earth spikes. (The Multiple Earthing System.)
  • True RMS. Accurate true RMS readings of AC current including distorted waveform from 1mA to 30.0A
  • Noise Check Function. A function to detect current, which effects on an earth resistance measurement and display "NOISE" mark on the LCD.
  • Memory function. Save and display up to 100 measurement data.
  • Data hold function / Buzzer function / Back light function
  • Compliant with Safety Standards of IEC 61010-1 : CAT.IV 300V Pollution degree2
Note:
A single earthing can not be measured. (Only for Multiple Earthing System)

Function
Range
Resolution
Measuring range
Accuracy
Earth resistance Auto range
20Ω
0.01Ω*
0.00~20.99Ω
|±1.5%±0.05Ω
200Ω
0.1Ω
16.0~99.9Ω
|±2%±0.5Ω
100.0~209.9Ω
|±3%±2Ω
1500Ω

160~399Ω
|±5%±5Ω
400~599Ω
|±10%±10Ω
10Ω
600~1580Ω
---
AC current
(50Hz / 60Hz)
Auto range
100mA
0.1mA
0.0~104.9mA
|±2%±0.7mA
1000mA
1mA
80~1049mA
|±2%
10A
0.01A
0.80~10.49A
30A
0.1A
8.0~31.5A
Operating system
Earth resistance function :
Constant voltage injection,
Current detection,
(Frequency : Approx.2400Hz)
Dual Integration
AC current function :
Successive Approximation
Over-range indication
"OL" is displayed when input exceeds the upper limit of a measuring range
Response time
Approx.7 seconds (Earth resistance)
Approx.2 seconds (AC current)
Sample rate
Approx. 1 times per second
Power source
DC6V : R6P (sizeAA manganese battery) × 4pcs,
or LR6 (sizeAA alkaline battery) × 4pcs
Current consumption
Approx. 50mA (max. 100mA)
Measurement time
Approx. 12 hours (when R6P is used)
Approx. 24 hours (when LR6 is used)
Auto power-off
Turns power off about 10 minutes after the last button operation.
Applicable standards
IEC 61010-1 : 2001 (CAT.IV 300V Pollution degree2)
Withstand voltage
AC5320Vrms / 5 seconds
Between the Transformer jaws fitted parts and Case enclosure
(except for jaws)
Conductor size
Approx. 32mm max.
Dimension
246(L) × 120(W) × 54(D)mm
Weight
Approx. 780g (including batteries)
Accessories
Battery R6P (AA) × 4, Instruction manual
8304 (Resister for operation check)
9166 (Hard case)
•Crest factor < 3 (50Hz / 60Hz, peak value shall not exceed 60A)