Senin, 25 April 2016

Siglent SHS1062 Handheld Oscilloscope (Dual-Channel, 60MHz Bandwidth)

Darmatek Alat Ukur dan Instrument

Siglent SHS1062 Handheld Oscilloscope (Dual-Channel, 60MHz Bandwidth)
  • Dual-channel oscilloscope
  • Multimeter built-in
  • 60MHz bandwidth
Description
Siglent SHS1062 Dual-Channel Handheld Oscilloscope (Bandwidth 60MHz) Details
The SHS1062 is a multifunction handheld oscilloscope that also includes a full digital multimeter and a recorder (TrendPlot and waveform Recorder).
Featuring bandwidth of 60MHz, this device is capable of measuring either single of dual-channel waveforms. When measuring single channel this device features real-time sample rate of 1GSa/s, and when measuring dual the sample rate is 500MSa/s. It also features equivalent sample rate of 50GSa/s and memory depth of 2Mpts.
The oscilloscope mode of this device also features multiple trigger types (Edge, Pulse, Video, Slope and Alternative), rise time of ≤5.8ns, vertical sensitivity of 5mV/div – 100V/div and 8 bit vertical resolution.
Thanks to the built-in multimeter included in this device the SHS1062 can also be used to gain accurate measurements of DC/AC voltage, DC/AC current, resistance, capacitance, diode and continuity across several different ranges. The display count of the multimeter is 6000.
The SHS1000 series also features Siglent’s patented IsolatedChannel technology which provides isolation from ground and between channels.
Siglent SHS1062 Handheld Oscilloscope Key Features
  • 2-channel device
  • Includes IsolatedChannel technology that isolates ground and between channels
  • 5.7 inch colour LCD display
  • 60MHz bandwidth
  • 6000 count multimeter measures DC/AC Voltage, DC/AC current, Resistance, Diode, Capacitance and Continuity
  • Includes Trendplot, Meter Trendplot and Scope recording functions
  • Automatic and manual trigger modes
  • Trigger types: Edge, Pulse, Video, Slope and Alternative
  • 32 automatic waveform measurements, 3 cursor measure modes
  • Digital filter functions: high pass, band pass, band limit
  • Mathematical functions: +, -, x, ÷ and FFT
  • Multiple language user interface
  • USB device and USB host with PC communication
  • Rechargeable battery
  • Ideal for multiple applications including power electronics, industrial power systems, field testing and more
Full List of Products Included
  • Siglent SHS1062 Handheld Digital Oscilloscope
  • 9V, 3A power adapter
  • Two oscilloscope probes: 1 x CAT II 1000V and 1 x CAT III 600V (100MHz)
  • Two test leads for multimeter measurements
  • USB data transmitting cable
  • User manual
  • Service warranty card
  • CD including Easyscope software
Technical Specification
ype SHS1062 SHS1102
Bandwidth 60MHz 100MHz
Rise Time ≤5.8ns ≤3.5ns
Real Time Sampling Rate Single Channel: 1GSa/s,
Double Channels: 500MSa/s
Single Channel: 1GSa/s,
Double Channels: 500MSa/s
Equivalent Sampling Rate 50GSa/s 50GSa/s
Memory Depth 2Mpts 2Mpts
Time Base Range 5 ns/ div – 50s/ div 2.5ns/ div – 50s/ div
Scan Range 100ms/ div ~ 50s/ div 100ms/ div ~ 50s/ div
Vertical Sensitivity 5mV/div – 100V/div(1-2-5 order) 5mV/div – 100V/div(1-2-5 order)
Vertical Resolution 8 bits 8 bits
Trigger Types Edge, Pulse, Video, Slope, Alternative Edge, Pulse, Video, Slope, Alternative
Frequency Counter 6 bits 6 bits
Connection USB Device, USB Host USB Device, USB Host
Math +, -, * , /, FFT +, -, * , /, FFT
Oscilloscope Trend Plot 800K points
Meter
Maximum Resolution 6000
DC Voltage 60mV
600mV—1000V
(±1%±15digit)
(±1%±5digit)
AC Voltage 60mV
600mV—750V
(±1%±15digit)
(±1%±5digit)
DC Current 60.00mA—600mA
6A—10A
(±1%±5digit)
(±1.5%±5digit)
AC Current 60.00mA—600mA
6A—10A
(±1%±5digit)
(±1.5%±5digit)
Resistance 600Ω—60MΩ (±1%±5digit)
Capacitance 40nF
400nF--400uF
(±3%±10digit)
(±4%±5digit)
Diode 0—2V
Continuity <50Ω Buzzer sounds
Multimeter Trend Plot 1.2M points
channels from earth ground,
between two channels
references
Overvoltage Category Maximum Voltage
CAT I&CAT II 1000 Vrms
CAT Ⅲ 600 Vrms
between Multimeter input
reference and the ground
Overvoltage Category Maximum Voltage
CAT I&CAT II 600 Vrms
CAT Ⅲ 300 Vrms
Max. input Voltage for BNC Overvoltage Category Maximum Voltage
1x CAT I&CAT II 300 Vrms
1X CAT Ⅲ 150 Vrms
10x CAT I&CAT II 1000 Vrms
10X CAT Ⅲ 600 Vrms
Max. input Voltage for
Multimeter input port
Voltage port DC 1000V, AC 750V
Current port(mA) AC 250V/600mA
Current port(A) AC 250V/10A
Single Channel Common
Mode Rejection, typical
>1000:1 50MHz
Channel-to-Channel
Isolation
>35 dB

General Feature
Display 5.7 inches color TFT-LCD, 320x234
Power supply With battery or DC adapter to get power from outside
Power source Built-in rechargeable lithium battery: 7.4V 5000mAh, Battery persisting 4 hours With DC adapter: 100-240V 50/60Hz input 9V 4A output.
Weight 1.5Kg
Dimension 163.2mm×259.5mm×53.3mm

0 komentar: