Senin, 18 April 2016

Kyoritsu KEW1051 Digital Multimeter


Kyoritsu 1051 Digital Multimeter
High Accuracy, High Performance and Reliable Measurements

  • 0.09% basic DC accuracy
  • Large display with 6,000 counts
  • True-RMS Measurements
  • True-RMS or MEAN value detection mode can be selected *
  • Low-pass filter for motor drive measurements
  • User calibration function
Safety design for industrial use
Complies with IEC 61010-1 CAT.IV 600V, CAT.III 1000V
Terminal shutter to prevent incorrect test leads' insertion in current terminals
Very wide operating temperature range from -10 to 55ºC
Reliable support for data management *

  • Large data internal memory *
KEW 1052: 1,600 data (logging), 100 data (manual)

  • Download data and Live Monitoring on a PC via the USB interface(Option for USB Communication set) *
* Only for KEW 1052
* MAX 32,767 data can be transferred.

Specification:


KEW 1051
KEW 1052
Detection mode
RMS
MEAN/RMS (switch)

DC V
600.0mV/6.000/60.00/600.0/1000V
(Input impedance: 10MΩ [600mV/60/600/1000V], 11MΩ [6V])
|±0.09%rdg±2dgt (Basic accuracy)
AC V [RMS] 600.0mV/6.000/60.00/600.0/1000V
(Input impedance: 10MΩ<200pF [600mV], 11MΩ<50pF [6V],
10MΩ<50pF [60/600/1000V])
|±0.5%rdg±5dgt (Basic accuracy)
DC A 600.0/6000µA/60.00/440.0mA/6.000/10.00A
|±0.2%rdg±2dgt (Basic accuracy)
AC A [RMS] 600.0/6000µA/60.00/440.0mA/6.000/10.00A
|±0.75%rdg±5dgt (Basic accuracy)
Ω 600.0Ω/6.000/60.00/600.0kΩ/6.000/60.00MΩ
|±0.4%rdg±1dgt (Basic accuracy)
Continuity buzzer 600.0Ω (The buzzer turns on for resistances lower than 50±30Ω)
Diode test 2.000V|±1%rdg±2dgt
Open curcuit voltage: <3.5V (Approx. 0.5mA Measuring Current)
Capacitance 10.00/100.0nF/1.000/10.00/100.0/1000µF
|±2%rdg±5dgt (Basic accuracy)
Frequency 10.00~99.99/90.0~999.9Hz/0.900~9.999/9.00~99.99kHz
|±0.02%rdg±1dgt (Basic accuracy)
Temperature -50~600ºC|±2%rdg±2ºC (with the use of K-type Temperature probe)
Other functions Data Hold (D/H), Auto Hold (A/H), Range Hold (R/H),
Maximum value (MAX) *, Minimum value (MIN) *, Average value (AVG) *, Zero Adjustment (Capacitor, Resistance), Save to Memory *,
LCD backlight
Withstand voltage 6,880V/5 sec.
Applicable standards IEC 61010-1 CAT.IV 600V, CAT.III 1000V Pollution degree 2,
IEC 61010-031, IEC 61326-1 (EMC)
Power source R6P (1.5V)×4 (Auto power off: approx. 20 minutes)
Dimensions 192(L)×90(W)×49(D) mm
Weight Approx. 560g (including batteries)
Accessories 220A (Test leads), R6P×4, Instruction manual,
8926 (Fuse [440mA/1000V])×1 (included)
8927 (Fuse [10A/1000V])×1 (included)

0 komentar: