Kyoritsu 1061 Digital Multimeter
High Accuracy, High Performance and Reliable Measurements
- 0.02% basic DC accuracy
- Large display with 50,000 counts
- Dual display for double indication for AC and DC, V and Hz, etc.
- True-RMS Measurements AC and AC+DC
- Wide AC Frequency bandwidth from 10Hz to 100kHz *
- True-RMS or MEAN value detection mode can be selected *
- Fast Peak Hold response time of 250µs
- Low-pass filter for motor drive measurements *
- Low Power Ω for resistance measurements on sensible electronic circuits by a low and safe test current*
- User calibration function
Safety design for industrial use
- Complies with IEC 61010-1 CAT.III 1000V, CAT.IV 600V
- Terminal shutter to prevent incorrect test leads' insertion in current terminals
- Very wide operating temperature range from -20 to 55ºC
- Large data internal memory
KEW 1061: 1,000 data (logging), 100 data (manual)
- Download data and Live Monitoring on a PC via the USB interface (Option for USB Communication set)
Specification:
| 
KEW 1061 | 
KEW 1062 | ||
| Detection mode | 
RMS | 
MEAN/RMS (switch) | |
| DC V | 50.000/500.00/2400.0mV/5.0000/50.000/500.00/1000.0V (Input impedance: Approx. 100MΩ [50/500/2400mV], 10MΩ [5/50/500/1000V]) |±0.02%rdg±2dgt (Basic accuracy) | ||
| AC V [RMS] | 50.000*/500.00mV/5.0000/50.000/500.00/1000.0V(* Only for 1062) (Input impedance: 11MΩ<50pF [50/500mV/5V], 10MΩ<50pF [50/500/1000V]) | ||
| ±0.7%rdg±30dgt (Basic accuracy) | ±0.4%rdg±30dgt (Basic accuracy) | ||
| AC V [MEAN] * | 
-- | 50.000/500.00mV/ 5.0000/50.000/500.00/1000.0V (Input impedance: 11MΩ<50pF [50/500mV/5V], 10MΩ<50pF [50/500/1000V]) |±1%rdg±30dgt (Basic accuracy) | |
| DCV+ACV | 5.0000/50.000/500.00/1000.0V (Input impedance: 11MΩ<50pF [5V], 10MΩ<50pF [50/500/1000V]) | ||
| ±1%rdg±10dgt (Basic accuracy) | ±0.5%rdg±10dgt (Basic accuracy) | ||
| DC A | 500.00/5000.0µA/50.000/500.00mA/5.0000/10.000A |±0.2%rdg±5dgt (Basic accuracy) | ||
| AC A [RMS] | 500.00/5000.0µA/50.000/500.00mA/5.0000/10.000A | ||
| ±1%rdg±20dgt (Basic accuracy) | ±0.75%rdg±20dgt (Basic accuracy) | ||
| AC A [MEAN] * | 
-- | 500.00/5000.0µA/50.000/500.00mA/ 5.0000/10.000A |±1.5%rdg±20dgt (Basic accuracy) | |
| DCA+ACA | 500.00/5000.0µA/50.000/500.00mA/5.0000/10.000A | ||
| ±1.5%rdg±10dgt (Basic accuracy) | ±1%rdg±10dgt (Basic accuracy) | ||
| Ω | 500.00Ω/5.0000/50.000/500.00kΩ/5.0000/50.000MΩ | ||
| ±0.1%rdg±2dgt (Basic accuracy) | ±0.05%rdg±2dgt (Basic accuracy) | ||
| LowPower-Ω * | 
-- | 5.000/50.00/500.0kΩ/5.000MΩ |±0.2%rdg±3dgt (Basic accuracy) | |
| Continuity buzzer | 500.0Ω (The buzzer turns on for resistances lower than 100±50Ω) | ||
| Diode test | 2.4000V|±1%rdg±2dgt Open curcuit voltage: <5V (Approx. 0.5mA Measuring Current) | ||
| Capacitance | 5.000/50.00/500.0nF/5.000/50.00/500.0µF/5.000/50.00mF |±1%rdg±5dgt (Basic accuracy) | ||
| Frequency | 2.000~9.999/9.00~99.99/90.0~999.9Hz/0.900~9.999/9.00~99.99kHz |±0.02%rdg±1dgt (Basic accuracy) | ||
| DUTY | 10~90%|±1%rdg | ||
| Temperature | -200~1372ºC|±1%rdg±1.5ºC -328~2501.6ºF|±1%rdg±2.0ºF (with the use of K-type Temperature probe) | ||
| Measurement functions | DC Voltage, AC Voltage, DC Current, AC Current, Resistance, Frequency, Temperature, Capacitor, Duty cycle ratio, Decibel (dBV, dBm), Continuity Check, Diode Test, LowPower-Ω * | ||
| Other functions | Data Hold (D/H), Auto Hold (A/H), Peak Hold * (P/H), Range Hold (R/H), Maximum value (MAX), Minimum value (MIN), Average value (AVG), Zero Adjustment (Capacitor, Resistance), Relative values, Save to Memory, LCD backlight | ||
| Withstand voltage | 6,880V/5 sec. | ||
| Applicable standards | IEC 61010-1 CAT.IV 600V, CAT.III 1000V Pollution degree 2, IEC 61010-031, IEC 61326-1 (EMC) | ||
| Power source | R6P (1.5V)×4 (Auto power off: approx. 20 minutes) | ||
| Dimensions | 192(L)×90(W)×49(D) mm | ||
| Weight | Approx. 560g (including batteries) | ||
| Accessories | 7220A (Test leads), R6P×4, Instruction manual, 8926 (Fuse [440mA/1000V])×1 (included) 8927 (Fuse [10A/1000V])×1 (included) | ||

 







 
 
 
 
 
 
 
 
 
 



 

0 komentar: