Kyoritsu 3128 12kV H. V. Insulation Tester
- Microprocessor controlled high voltage insulation resistance tester with Diagnostic functions.
- Suitable for analyzing the insulation characteristics of cables, transformers, motors, generators, high-pressure switches, insulators, wiring installations, etc.
- 6 ranges: 500V, 1000V, 2500V, 5000V, 10000V, 12000V
- Fine adjustment of voltage setting at each range is also possible
- Graphic representation of the insulation resistance and leakage current versus time on large display with bar graph and backlight.
- Can be operated from built-in rechargeable battery or from AC line.
- Automatic discharge after test with monitoring of the discharge voltage.
- Internal memory can store about 43,000 data (max).
- Robust design for field use with IP64 rating (with lid closed).
Insulation resistance (*) : Accuracy is not guaranteed with setting of 250V or less
|
||||||
Rated voltage | 500V | 1000V | 2500V | 5000V | 10000V | 12000V |
Max. measurement value | 500GΩ | 1TΩ | 2.5TΩ | 5TΩ | 35TΩ | |
Accuracy |
400k~50GΩ ±5%rdg±3dgt (*) |
800k~100GΩ ±5%rdg±3dgt |
2M~250GΩ ±5%rdg±3dgt |
4M~500GΩ ±5%rdg±3dgt |
8M~1TΩ ±5%rdg±3dgt |
|
50G~500GΩ ±20%rdg (*) |
100G~1TΩ ±20%rdg |
250G~2.5TΩ ±20%rdg |
500G~5TΩ ±20%rdg |
1T~10TΩ ±20%rdg |
||
10T~35TΩ Values are displayed, but accuracy isn't guaranteed |
||||||
Short circuit current | Max 5.0mA | |||||
Load resistor to output rated voltage | 0.5MΩ or more | 1MΩ or more | 2.5MΩ or more | 5MΩ or more | 20MΩ or more | 24MΩ or more |
Output Voltage
|
||||||
Rated Voltage | 500V | 1000V | 2500V | 5000V | 10000V | 12000V |
Monitor Accuracy | ±10%±20V | ±10%±20V | ±10%±20V | ±10%±20V | ±10%±20V | ±10%±20V |
Output Accuracy | 0~+20% | 0~+10% | 0~+10% | 0~+10% | -5~+5% | -5~+5% |
Selectable range | 50~600V (in steps of 5V) |
610~1200V (in steps of 10V) |
1225~3000V (in steps of 25V) |
3050~6000V (in steps of 50V) |
6100~10000V (in steps of 100V) | 10100~ 12000V (in steps of 100V) |
Voltage measurement
|
||||||
Measuring range | DCV : ±30~±600V, ACV : 30~600V (50/60Hz) | |||||
Accuracy | ±2%rdg±3dgt | |||||
Current measurement
|
||||||
Measuring range | 0.00nA~2.40mA (Depending on the insulation resistance) | |||||
Capacitance measurement
|
||||||
Measuring range | 5.0nF~50.0µF | 5.0nF~1.0µF (display range: 5.0nF~50.0µF) |
||||
Accuracy | ±5%rdg±5dgt | |||||
General
|
||||||
Withstand voltage | AC8770V : between line terminal and enclosure / 5sec (50/60Hz) AC6880V : between the measuring terminal and enclosure / 5sec (50/60Hz) AC2330V : between the power connector and enclosure / 5sec (50/60Hz) |
|||||
Operating temperature & humidity range | -10°C ~ 50°C /Relative humidity 85% or less (when operating with an external power supply, no condensation) 0°C ~ 40°C /Relative humidity 85% or less (when operating with battery, no condensation) |
|||||
Storage temperature & humidity range | -20ºC~60ºC / Relative humidity 75% or less (no condensation) |
|||||
Applicable standards | IEC 61010-1 CAT.IV 600V Pollution degree 2, IEC 61010-031, IEC 61326, IEC 60529 (IP64): with the lid closed. |
|||||
Power source |
Rechargeable Lead storage battery (12V)* Charging time: approx. 8 hours / AC Power supply (100V~240V, 50/60Hz) * Continuous measuring time: approx. 4 hours (a load of 100MΩ at the Insulation resistance 12000V Range.) approx. 2 hours (Max current consumption in range while rated currents are maintained.) |
|||||
Dimension | 330 (L) × 410 (W) × 180 (D) mm *Instrument and Hard case | |||||
Weight | 9kg approx. (including battery) *Instrument and Hard case | |||||
Accessories | 7170 (Main cord), 7224A (Earth cord), 7225A (Guard cord), 7226A (Line probe), 7227A (Line probe with alligator clip), 8029 (Extension prod), 8212-USB-W (USB adaptor with KEW Windows(Software)), Instruction manual, Calibration Certificate | |||||
Optional | 7254 (Longer Line probe with alligator clip) |
0 komentar: