LUTRON DW-6060 Digital Watt Meter
Features
The Digital Watt Meter give a
direct reading of Watt value on 3 ½ digits LCD display, five range and
functions give precision reading to the ACV, ACA, DCV, DCA, and WATT. Then to
NEW type of performance that make them them ideal for many applications
including industry, labs, service shop and shools. It can be requiring to
accurate current, voltage, and true power measurement.
- Digital display, easy and correct read-out
- Reads true power, not apparent power
- Use with single-phase power source
- DC 9 Volt batteries operated
- In build low battery indicator
- LCD display provides low power consumption
- LCD display allow clear read-out even in bright ambient light condition
- Compact, light-weight, and excellent for operation
- It is easy for one hand operation by pushing button.
- Color-coded panel assures easy operation
General Specifications
Display
|
0.5” LCD (Liquid Crystal
Display), Max. Indication 1999
|
Measurement
|
Watt (true power), DCV,ACV,DCA,
ACA
|
Polarity
|
Bi-Polar by automatic
Switching, “-“ indicates reverse polarity
|
Zero Adjust
|
Watt :
External adjustment for zero of
the display, limited to +30 to -30 digits.
ACV/DCV/ACA/DCA :
Automatic Adjustment
|
Over-input
|
Indication of “1” or “-1”
|
Operating Temp.
|
0°C to 50°C (32°F to 122°F)
|
Operating Humidity
|
Less than 80% RH
|
Power Supply
|
006P DC 9V battery. (heavy duty
or alkaline battery)
|
Power Consumption
|
Approx. DC 6 mA
|
Weight
|
500g (including battery)
|
Standard Accessories
|
Test lead ….. 1 Pair
Instruction Manual ….. 1 PC
|
Electrical Specifications (23 ± 5°C)
AC WATT (true power)
|
|||
Range
|
Accuracy
|
Resolution
|
Overload Circuit Protection
|
2000W
|
±(1% + 1d)
|
1W
|
ACV : 600 ACV
ACA : 10 ACA
|
6000W
|
±(1% + 1d)
|
10W
|
|
* Input Voltage : 0 to 600 ACV
* Input Current : 0 to 10 ACA
* Frequency Characteristic : 45
Hz - 65 Hz
* Accuracy spec. Tested on
input voltage >60 ACA (60Hz)
|
AC VOLTAGE
|
|||
Range
|
Accuracy
|
Resolution
|
Overload Circuit Protection
|
200V
|
±(0.8% + 1d)
|
0.1V
|
ACV : 600 ACV
DCV : ± 600 DCV
|
600V
|
±(0.8% + 1d)
|
1V
|
|
* Frequency Characteristic : 45
Hz - 65 Hz
* Converter Response :
Average
responding, calibrated to display RMS value of sine wave
* Input Impedance : 1 Mega ohm
|
AC CURRENT
|
|||
Range
|
Accuracy
|
Resolution
|
Max. Input Current
|
10A
|
±(1% + 1d)
|
10mA
|
10A
|
* Voltage drop (in case of full
scale) : 200 AC mV
* Frequency Characteristic : 45
Hz - 65 Hz
* Converter Response :
Average
responding, calibrated to display RMS value of sine wave
|
DC VOLTAGE
|
|||
Range
|
Accuracy
|
Resolution
|
Overload Circuit Protection
|
200V
|
±(0.8% + 1d)
|
0.1V
|
ACV : 600 ACV
|
600V
|
±(0.8% + 1d)
|
1V
|
DCV : ± 600 DCV
|
* Input Impedance : 1 Mega ohm
|
DC CURRENT
|
|||
Range
|
Accuracy
|
Resolution
|
Max. Input Current
|
10A
|
±(1% + 1d)
|
10mA
|
10A
|
* Voltage drop (in
case of full scale) : 200 DC mV
|