Selasa, 19 April 2016

LUTRON DW-6060 Digital Watt Meter

Darmatek Alat Ukur dan Instrument


LUTRON DW-6060 Digital Watt Meter

Features
The Digital Watt Meter give a direct reading of Watt value on 3 ½ digits LCD display, five range and functions give precision reading to the ACV, ACA, DCV, DCA, and WATT. Then to NEW type of performance that make them them ideal for many applications including industry, labs, service shop and shools. It can be requiring to accurate current, voltage, and true power measurement.
  • Digital display, easy and correct read-out
  • Reads true power, not apparent power
  • Use with single-phase power source
  • DC 9 Volt batteries operated
  • In build low battery indicator
  • LCD display provides low power consumption
  • LCD display allow clear read-out even in bright ambient light condition
  • Compact, light-weight, and excellent for operation
  • It is easy for one hand operation by pushing button.
  • Color-coded panel assures easy operation
General Specifications
Display
0.5” LCD (Liquid Crystal Display), Max. Indication 1999
Measurement
Watt (true power), DCV,ACV,DCA, ACA
Polarity
Bi-Polar by automatic Switching, “-“ indicates reverse polarity
Zero Adjust
Watt :
External adjustment for zero of the display, limited to +30 to -30 digits.
ACV/DCV/ACA/DCA :
Automatic Adjustment
Over-input
Indication of “1” or “-1”
Operating Temp.
0°C to 50°C (32°F to 122°F)
Operating Humidity
Less than 80% RH
Power Supply
006P DC 9V battery. (heavy duty or alkaline battery)
Power Consumption
Approx. DC 6 mA
Weight
500g (including battery)
Standard Accessories
Test lead ….. 1 Pair
Instruction Manual ….. 1 PC


Electrical Specifications (23 ± 5°C)
AC WATT (true power)
Range
Accuracy
Resolution
Overload Circuit Protection
2000W
±(1% + 1d)
1W
ACV : 600 ACV
ACA : 10 ACA
6000W
±(1% + 1d)
10W
* Input Voltage : 0 to 600 ACV
* Input Current : 0 to 10 ACA
* Frequency Characteristic : 45 Hz - 65 Hz
* Accuracy spec. Tested on input voltage >60 ACA (60Hz)

AC VOLTAGE
Range
Accuracy
Resolution
Overload Circuit Protection
200V
±(0.8% + 1d)
0.1V
ACV : 600 ACV
DCV : ± 600 DCV
600V
±(0.8% + 1d)
1V
* Frequency Characteristic : 45 Hz - 65 Hz
* Converter Response :
   Average responding, calibrated to display RMS value of sine wave
* Input Impedance : 1 Mega ohm

AC CURRENT
Range
Accuracy
Resolution
Max. Input Current
10A
±(1% + 1d)
10mA
10A
* Voltage drop (in case of full scale) : 200 AC mV
* Frequency Characteristic : 45 Hz - 65 Hz
* Converter Response :
   Average responding, calibrated to display RMS value of sine wave

DC VOLTAGE
Range
Accuracy
Resolution
Overload Circuit Protection
200V
±(0.8% + 1d)
0.1V
ACV : 600 ACV
600V
±(0.8% + 1d)
1V
DCV : ± 600 DCV
* Input Impedance : 1 Mega ohm


DC CURRENT
Range
Accuracy
Resolution
Max. Input Current
10A
±(1% + 1d)
10mA
10A
* Voltage drop (in case of full scale) : 200 DC mV


0 komentar: