Rabu, 11 Mei 2016

HANNA HI98186 Dissolved Oxygen and BOD Meter

Darmatek

HANNA HI 98186 Dissolved Oxygen and BOD Meter
  • Extended DO range up to 50 ppm and 600% saturation
  • Built-in barometer
  • Salinity, pressure and temperature compensation
  • Backlit, graphic LCD display
  • Calibration reminder
  • Log on demand (400 samples)
  • Auto HOLD
  • GLP features
  • PC connectivity via USB
HI 98186 portable Dissolved Oxygen Meter has extended ranges of up to 50 ppm or 600% saturation. This instrument includes barometric pressure measurement and calibration with a user selectable unit (mmHg, atm, mbar, psi, kPa) as well as a 1 or 2 point temperature calibration. Salinity, pressure and temperature compensations enhance the precision of your readings.

With its internal barometer, the instrument is able to automatically compensate for changes in barometric pressure so there is no need for charts, altitude information or external barometric pressure information. Salinity compensation in water allows direct determination of dissolved oxygen in saline waters.
Other features include measurement and methods for BOD (biochemical oxygen demand), OUR (oxygen uptake rate), and SOUR (specific oxygen uptake rate).

The HI 98186’s log on-demand features allows users to store up to 400 samples that can be later transferred to a PC with the HI?920013 USB cable and HI 92000 software.
An “Out Of Calibration Range Warning” can be activated to alert the user in the event that a reading is taken too far from the calibration's periphery. A combination of dedicated and soft keys allows easy, intuitive operation in a choice of languages. 

Comprehensive GLP data is directly accessible by pressing the GLP key and a contextual Help menu can be access to obtain on-screen information and assistance about each feature at the touch of a button.
Designed for field use, this instrument can be easily operated with one hand and is housed in a rugged carrying case. The inductive charger can either be plugged into a standard 115V socket with the adapter included or a 12 VDC source, such as a car's 12 V accessory outlet.

Order Information:
HI 98186-01 (115V) and HI 98186-02 (230V) are supplied with HI 76407/4F DO probe, spare membranes (2), HI 7041S electrolyte solution (30 mL), rechargeable batteries, HI 710042 inductive battery charger with power adapter, 12 VDC adapter, instructions and rugged carrying case.

Specification

Range DO 0.00 to 50.00 mg/L (ppm); 0.0 to 600.0 % saturation
Barometric
Pressure
450 to 850 mmHg
Temperature -20.0 to 120.0°C (-4.0 to 248.0°F)
Resolution DO 0.01 mg/L (ppm); 0.1% saturation
Barometric
Pressure
1 mm Hg
Temperature 0.1°C/°F
Accuracy (@20°C) DO ±1.5% of reading ±1 digit
Barometric
Pressure
± 3 mmHg within ±15% from the calibration point
Temperature ±0.2°C/±0.4°F (excluding probe error)
Measurement
Modes

direct DO; BOD (biochemical oxygen demand); OUR (oxygen uptake rate); SOUR (specific oxygen uptake rate)
Calibration DO automatic one or two point at 100 % (8.26 mg/L) and 0 % (0 mg/L).; manual one point using a value entered by the user in % saturation or mg/L
Barometric
Pressure
one point at any in range pressure value
Temperature one or two point at any in range temperature value
Compensation Barometric automatic from 450 to 850 mmHg
Salinity automatic from 0 to 70 g/L
Temperature automatic from 0.0 to 50.0 ºC (32.0 to 122.0 ºF)
Probe
HI 76407/4F polarographic DO probe with protective sleeve, internal temperature sensor, DIN connector and 4m (13’) cable (included)
Logging
log on demand, 400 samples
PC Connection
opto-isolated USB (with HI?92000 software)
Battery Type / Life
1.2V (4) AA rechargeable batteries/approximately 200 hours of continuous use without backlight
Auto-off
user selectable: 5, 10, 30, 60 min or can be disabled
Environment
0 – 50 ºC (32 – 122 ºF) RH max 100%
Dimensions
226.5 x 95 x 52 mm (8.9 x 3.75 x 2”)
Weight
525 g (1.1 lbs.)

0 komentar: